| Electronic Components Datasheet Search |
|
TLE6288R Datasheet(PDF) 6 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLE6288R Datasheet(HTML) 6 Page - Infineon Technologies AG |
|
6 / 32 page ![]() TLE6288R Pin Configuration Data Sheet 6 Rev. 2.5, 2010-10-11 2.3 Pin Description 17 DOUT5 Drain Output CH 5 (high/low side) 18 SOUT5 Source Output CH 5 (high/low side) 19 SOUT3 Source Output CH 3 (high side) 20 DOUT3 Drain Output CH 3 (high side) 21 VCP Charge Pump capacitor pin 22 FSIN All Channels Enable/Disable 23 GND Logic Ground 24 Fault General Fault Flag 25 IN3 Control Input Channel 3 26 IN6 Control Input Channel 6 27 Reset Reset pin (+ Standby Mode) 28 V CC Logic Supply Voltage (5 V) 29 V DO Supply pin for digital outputs 30 SO SPI Serial Data Output 31 CLKProg Program pin of SPI Clock 32 SCLK SPI Serial Clock 33 CS SPI Chip Select 34 SI SPI Serial Data Input 35 DOUT6 Drain Output CH 6 (high/low side) 36 SOUT6 Source Output CH 6 (high/low side) Symbol Description DOUT1-3 Drain of the 3 highside channels. These pins must always be connected to the same power (battery) supply line ( V B). SOUT1-3 Source of the 3 highside channels. Outputs of the highside channels where the load is connected. DOUT4-6 Drain pins of the 3 configurable channels. In highside configuration they must be connected to the same voltage as DOUT1-3. In lowside configuration they are the output pins and connected to the load. SOUT4-6 Source of the 3 configurable channels. In highside configuration they are the outputs and connected to the load. In lowside configuration they must be connected with GND. IN1-6 Parallel input pins for the 6 power outputs. These pins have an internal pull-down structure. GND Logic ground pin, the heat slug has to be connected to this potential. FSIN Disable pin. If the FSIN pin is in a logic low state, it switches all outputs OFF. The pin has an internal pull-up structure. Reset Reset pin. When the reset is low all channels are off, the internal biasing is deactivated, all internal registers are cleared and the supply-current consumption is reduced (standby mode). The pin has an internal pull-up structure. Fault General Fault pin. There is a general fault pin (open drain) which shows a high to low transition as soon as an error is latched into the diagnosis register. When the diagnosis register is cleared this flag is also reset (high ohmic). This fault indication can be used to generate a μC interrupt. Pin Symbol Function |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |