| Electronic Components Datasheet Search |
|
VCM-DAS-3 Datasheet(PDF) 28 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
VCM-DAS-3 Datasheet(HTML) 28 Page - List of Unclassifed Manufacturers |
|
28 / 42 page ![]() External Trigger Enable Register VCM-DAS-3 Reference Manual 23 External Trigger Enable Register EXTRIG (Read/Write) 0303h 7 6 5 4 3 2 1 0 – – – – – – – TRIGEN Table 14: EXTRIG Bit Assignments Bit Mnemonic Description 7-1 – Unused. These bits have no function. 0 TRIGEN Trigger Enable – When the external trigger is enabled, digital I/O line C0 will update all DACs simultaneously when it is brought low. This can be done either by an external signal, when C0 is in input mode, or in software, when C0 is in output mode. If using an external trigger, make sure that the lower half of Port C is in input mode. 1 = Enable 0 = Disable |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|