Back Button HT9480 Datasheet HTML 49Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 50Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 51Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 52Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 53Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 54Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 55Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 56Page - Holtek Semiconductor Inc HT9480 Datasheet HTML 57Page - Holtek Semiconductor Inc  
Zoom Inzoom in Zoom Outzoom out
 55 / 57 page
background image
SUB A,x
Subtract immediate data from accumulator
Description
The immediate data specified by the code is subtracted from the contents of
the accumulator, leaving the result in the accumulator.
Operation
ACC
← ACC+x+1
Affected flag(s)
TC2
TC1
TO
PD
OV
Z
AC
C
––
–
–
√√
√√
SWAP [m]
Swap nibbles within the data memory
Description
The low-order and high-order nibbles of the specified data memory (one of the
data memories) are interchanged.
Operation
[m].3~[m].0
↔ [m].7~[m].4
Affected flag(s)
TC2
TC1
TO
PD
OV
Z
AC
C
–
–
––
––
––
SWAPA [m]
Swap data memory-place result in accumulator
encryption
The low-order and high-order nibbles of the specified data memory are
interchanged, writing the result to the accumulator. The contents of the data
memory remain unchanged.
Operation
ACC.3~ACC.0
← [m].7~[m].4
ACC.7~ACC.4
← [m].3~[m].0
Affected flag(s)
TC2
TC1
TO
PD
OV
Z
AC
C
–
–
––
––
––
SZ [m]
Skip if data memory is zero
Description
If the contents of the specified data memory is zero, the following instruction,
fetched during the current instruction execution, is discarded and a dummy
cycle is replaced to get the proper instruction. This is a 2-cycle instruction.
Otherwise proceed with the next instruction.
Operation
Skip if [m]=0
Affected flag(s)
TC2
TC1
TO
PD
OV
Z
AC
C
–
–
––
––
––
HT9480
55
23th Feb ’98



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com