Back Button MAX127ACAI Datasheet HTML 8Page - Maxim Integrated Products MAX127ACAI Datasheet HTML 9Page - Maxim Integrated Products MAX127ACAI Datasheet HTML 10Page - Maxim Integrated Products MAX127ACAI Datasheet HTML 11Page - Maxim Integrated Products MAX127ACAI Datasheet HTML 12Page - Maxim Integrated Products MAX127ACAI Datasheet HTML 13Page - Maxim Integrated Products MAX127ACAI Datasheet HTML 14Page - Maxim Integrated Products MAX127ACAI Datasheet HTML 15Page - Maxim Integrated Products MAX127ACAI Datasheet HTML 16Page - Maxim Integrated Products  
Zoom Inzoom in Zoom Outzoom out
 15 / 16 page
background image
Transfer Function
Output data coding for the MAX127/MAX128 is binary
in unipolar mode with 1LSB = (FS/4096) and
two’s complement binary in bipolar mode with 1LSB =
[(2 x | FS |) / 4096]. Code transitions occur halfway
between successive-integer LSB values. Figures 13a
and 13b show the input/output (I/O) transfer functions
for unipolar and bipolar operations, respectively. For
full-scale (FS) values, refer to Table 3.
Layout, Grounding, and Bypassing
Careful printed circuit board layout is essential for best
system performance. For best performance, use a
ground plane. To reduce crosstalk and noise injection,
keep analog and digital signals separate. Connect ana-
log grounds and DGND in a star configuration to
AGND. For noise-free operation, ensure the ground
return from AGND to the supply ground is low imped-
ance and as short as possible. Connect the logic
grounds directly to the supply ground. Bypass VDD with
0.1µF and 4.7µF capacitors to AGND to minimize high-
and low-frequency fluctuations. If the supply is exces-
sively noisy, connect a 5
Ω resistor between the supply
and VDD, as shown in Figure 14.
Multirange, +5V, 12-Bit DAS with
2-Wire Serial Interface
______________________________________________________________________________________
15
OUTPUT CODE
INPUT VOLTAGE (LSB)
0
FS
FS - 3/2 LSB
1 LSB =
FULL-SCALE
TRANSITION
1
2
3
11... 111
11... 110
11... 101
00... 011
00... 010
00... 001
00... 000
FS
4096
Figure 13a. Unipolar Transfer Function
OUTPUT CODE
INPUT VOLTAGE (LSB)
0
+FS - 1 LSB
1 LSB =
-FS
011... 111
011... 110
000... 001
000... 000
111... 111
100... 010
100... 001
100... 000
2
FS
4096
Figure 13b. Bipolar Transfer Function
VDD
GND
DGND
DGND
AGND
+5V
+5V
SUPPLY
R* = 5
Ω
DIGITAL
CIRCUITRY
4.7
µF
0.1
µF
MAX127
MAX128
**
* OPTIONAL
** CONNECT AGND AND DGND WITH A GROUND PLANE OR A SHORT TRACE.
Figure 14. Power-Supply Grounding Connection



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com