| Electronic Components Datasheet Search |
|
LMP8358MA/NOPB Datasheet(PDF) 30 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LMP8358MA/NOPB Datasheet(HTML) 30 Page - Texas Instruments |
|
30 / 40 page ![]() 100 PA 1k 2.55V 2.5V + - +5V 1k 1k 1k 1k 2.5V +IN -IN OUT +5V V + 100 PA 1k 2.65V 2.55V + - +5V 1k 1k 1k 1k 2.5V +IN -IN OUT +5V V + LMP8358 SNOSB09B – APRIL 2010 – REVISED MARCH 2013 www.ti.com Degraded Input Line Figure 59 shows an example of a degraded connection between the bridge and the +IN pin of the LMP8358. This fault is shown by the 1 k Ω resistor placed between the bridge and the LMP8358. To detect this fault use the 1/50 feature by setting MUX[1:0] to 10b to test the +IN pin, POL to 0b, and G[2:0] to 010b for a gain of 50. This will give an overall gain of 1. Set CUR[2:0] = 101b to inject a 100µA current and read the output voltage (5082x). Next set MUX[1:0] to 11b and PIN to 1b to test the −IN pin as shown in Figure 60 and read the output (58C2x). If the voltages of these two measurements are different a degraded input fault exists. Figure 59. Degraded Input Line, Step 1 Figure 60. Degraded Input Line, Step 2 Fault Detection Example Using the fault detection features of the LMP8358 an end product, such as a scale, can periodically test that no damage has occurred to the system. A routine can be written that could, for example, run on start up, that will step through the fault detection features shown above and compare the output voltage to a table like that shown in Table 16. If the circuit shown in Figure 54 is used the values shown in column 2 of Table 16 would show that the system is working correctly, the values in the columns under the Possible Faults heading would show that there is a potential problem and that operator attention is needed. Table 16. Fault Detection Matrix No Faults Possible Faults LMP8358 VOUT VOUT Possible Cause VOUT Possible Cause VOUT Possible Cause Register 00 82x 2.5V VOUT < CMVR or Input is out of V+ +IN shorted to V+ 0V +IN shorted to VOUT > CMVR CMVR GND 00 C2x 2.5V VOUT < CMVR or Input is out of V+ −IN shorted to V+ 0V −IN shorted to VOUT > CMVR CMVR GND 50 00x 0.61V V+ +IN Open 0.07V Inputs shorted 50 03x 4.97V V+ −IN 0.7V Inputs shorted 50 82x 2.55V 2.65V* Degraded +IN line 58 C2x 2.55V 2.55V* Degraded +IN line 50 82x 2.55V 2.55V* Degraded −IN line 30 Submit Documentation Feedback Copyright © 2010–2013, Texas Instruments Incorporated Product Folder Links: LMP8358 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |