| Electronic Components Datasheet Search |
|
TMP47C101 Datasheet(PDF) 14 Page - Toshiba Semiconductor |
|
|
|||||||||||||||||||||||||||||
TMP47C101 Datasheet(HTML) 14 Page - Toshiba Semiconductor |
|
14 / 32 page ![]() 14/32 TOSHIBA CORPORATION TMP47C101/201 2.7.4 Hold Operating Mode The hold feature stops the system and holds the system’s internal states active before stop with a low power. The hold operation is controlled by the command register (OP10) and the HOLD pin input. The HOLD pin input state can be known by the status register (IPOE). The HOLD pin is wired with the R82 output latch. To use this port for hold operating mode, the R82 output latch should be set to “1”. (1) Starts Hold Operating Mode The hold operating mode consists of the level-sensitive release mode and the edge-sensitive release mode. The hold operation is started when the command is set to the command register and holds the following states during the hold operation: The oscillator stops and the system’s internal opera- tions are all held up. The timing generator is cleared to “0”. The states of the data memory, registers, and latches valid immediately before the system is put in the hold state are all held. The program counter holds the address of the in- struction to be executed after the instruction ([OUT A, %OP10] or [OUT @HL, %OP10]) which starts the hold operating mode. Figure 2-18. Hold Operating Mode Command Register/Status Register a. Level-sensitive release (back-up) mode In this mode, the hold operation is released by setting the HOLD pin to the high level. This mode is used for the capacitor backup with power off or for the battery backup for long hours. If the instruction to start the hold operation is executed with the HOLD pin input being high, the hold operation does not start but the release sequence (warm-up) starts immediately. Therefore, to start the hold opera- tion in the level-sensitive release mode, that the HOLD pin input being low (the hold operation request) must be recognized in program. This recognition is per- formed in one of the two ways below: Testing HOLD (bit 0 of the status register) Generating the external interrupt 1 request. Example: To test HOLD to start the hold operation in the level-sensitive release mode (the warm- up time = 214/fc). SHOLDH: TEST %IPOE, 0 ; Waits until HOLD pin input goes low. B SHOLDH LD A, #1101B ; OP10 ←1101 B OUT A, %OP10 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |