| Electronic Components Datasheet Search |
|
TMS320F28075PZP Datasheet(PDF) 116 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMS320F28075PZP Datasheet(HTML) 116 Page - Texas Instruments |
|
116 / 192 page ![]() 7.11.4 High-Resolution Pulse Width Modulator (HRPWM) The HRPWM combines multiple delay lines in a single module and a simplified calibration system by using a dedicated calibration delay line. For each ePWM module, there are two HR outputs: • HR Duty and Deadband control on Channel A • HR Duty and Deadband control on Channel B The HRPWM module offers PWM resolution (time granularity) that is significantly better than what can be achieved using conventionally derived digital PWM methods. The key points for the HRPWM module are: • Significantly extends the time resolution capabilities of conventionally derived digital PWM • This capability can be used in both single edge (duty cycle and phase-shift control) as well as dual edge control for frequency/period modulation. • Finer time granularity control or edge positioning is controlled through extensions to the Compare A, B, phase, period and deadband registers of the ePWM module. Note The minimum HRPWMCLK frequency allowed for HRPWM is 60 MHz. 7.11.4.1 HRPWM Electrical Data and Timing Section 7.11.4.1.1 lists the high-resolution PWM timing requirements. Section 7.11.4.1.2 lists the high-resolution PWM switching characteristics. 7.11.4.1.1 High-Resolution PWM Timing Requirements MIN MAX UNIT f(EPWM) Frequency, EPWMCLK(1) 100 MHz f(HRPWM) Frequency, HRPWMCLK 60 100 MHz (1) For SYSCLK above 100 MHz, the EPWMCLK must be half of SYSCLK. 7.11.4.1.2 High-Resolution PWM Characteristics PARAMETER MIN TYP MAX UNIT Micro Edge Positioning (MEP) step size(1) 150 310 ps (1) The MEP step size will be largest at high temperature and minimum voltage on VDD. MEP step size will increase with higher temperature and lower voltage and decrease with lower temperature and higher voltage. Applications that use the HRPWM feature should use MEP Scale Factor Optimizer (SFO) estimation software functions. See the TI software libraries for details of using SFO functions in end applications. SFO functions help to estimate the number of MEP steps per SYSCLK period dynamically while the HRPWM is in operation. TMS320F28076, TMS320F28075 SPRS902J – OCTOBER 2014 – REVISED FEBRUARY 2021 www.ti.com 116 Submit Document Feedback Copyright © 2021 Texas Instruments Incorporated Product Folder Links: TMS320F28076 TMS320F28075 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |