27 / 28 page ![]() Data may be changed without notice - Proprietary information of Yamar Electronics Ltd. ©2019-2022 Yamar Electronics Ltd. 27 DS-DMX250 R 0.80 www.yamar.com Tel: +972-3-5445294 Fax: +972-3-5445279 9. Test Environment Figure 19 depicts a typical DC-BUS Test environment that allows testing the DMX250 devices in an emulated lab DC powerline environment. Figure 19 - DC-BUS Test environment This test environment consists of two DMX250 evaluation boards (EVB), and two users' DMX-controllers. The DC- powerline attenuator is optional. The DC-powerline attenuator is used to test the communication in variable attenuation levels (0-61dB), emulating a DC powerline environment. When connecting the EVB directly to a power supply, it is recommended to add in serial to the power supply an inductor (>22uH) to avoid strong attenuation due to the power supply input filtering capacitors. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|