| Electronic Components Datasheet Search |
|
MIC2593 Datasheet(PDF) 18 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
MIC2593 Datasheet(HTML) 18 Page - STMicroelectronics |
|
18 / 26 page ![]() MIC2593 Micrel M9999-042204 18 April 2004 Status Register Slot A (STATA) 8-Bits, Read-Only Status Register, Slot A (STATA) D[7] D[6] D[5] D[4] D[3] D[2] D[1] D[0] read-only read-only read-only read/write read/write read/write read/write read/write FAULTA MAINA VAUXA VAUXAF 12MVAF 12VAF 5VAF 3VAF Bit(s) Function Operation FAULTA FAULT Status – Slot A 1 = /FAULTA pin asserted (/FAULTA pin is LOW) 0 = /FAULTA pin de-asserted (/FAULTA pin is HIGH) See Notes 1 and 2 MAINA MAIN Enable Status – Slot A Represents the actual state (on/off) of the four Main Power outputs for Slot A (+12V, –12V, +5V and +3.3V) 1 = Main Power ON 0 = Main Power OFF VAUXA VAUX Enable Status – Slot A Represents the actual state (on/off) of the Auxiliary Power output for Slot A 1 = AUX Power ON 0 = AUX Power OFF VAUXAF Overcurrent Fault: VAUXA supply A 1 = Fault 0 = No fault 12MVAF Overcurrent Fault: –12V supply A 1 = Fault 0 = No fault 12VAF Overcurrent Fault: +12V supply A 1 = Fault 0 = No fault 5VAF Overcurrent Fault: 5V supply A 1 = Fault 0 = No fault 3VAF Overcurrent Fault: 3.3V supply A 1 = Fault 0 = No fault Power-Up Default Value: 0000 0000 b = 00h Command_Byte Value (R/W): 0000 0100 b = 04h The power-up default value is 00 h. Both slots are disabled upon power-up, i.e., all supply outputs are off. In response to an overcurrent fault condition, writing a logical 1 back into the active (or set) bit position will clear the bit and de-assert /INT. The status of the /FAULTA pin is not affected by reading the Status Register or by clearing active status bits. Notes: 1. If FAULTA has been set by an overcurrent condition on one or more of the MAIN outputs, the ONA input must go LOW to reset FAULTA. If FAULTA has been set by a VAUXA overcurrent event, the AUXENA input must go LOW to reset FAULTA. If an overcurrent has occurred on both a MAIN output and the VAUX output of slot A, both ONA and AUXENA of the slot must go low to reset FAULTA. 2. Neither the FAULTA bit nor the /FAULTA pin is active when the MIC2593 power paths are controlled by the System Management Interface. When using SMI power path control, AUXENA and ONA pins for that slot must be tied to GND. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |