| Electronic Components Datasheet Search |
|
AR0130CSSC00SPBA0-DP1 Datasheet(PDF) 14 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
AR0130CSSC00SPBA0-DP1 Datasheet(HTML) 14 Page - ON Semiconductor |
|
14 / 40 page ![]() AR0130CS www.onsemi.com 14 FEATURES See the AR0130 Register Reference for additional details. Reset The AR0130 may be reset by using RESET_BAR (active LOW) or the reset register. Hard Reset of Logic The RESET_BAR pin can be connected to an external RC circuit for simplicity. The recommended RC circuit uses a 10 k W resistor and a 0.1 mF capacitor. The rise time for the RC circuit is 1 ms maximum. Soft Reset of Logic Soft reset of logic is controlled by the R0x301A Reset register. Bit 0 is used to reset the digital logic of the sensor while preserving the existing two−wire serial interface configuration. Furthermore, by asserting the soft reset, the sensor aborts the current frame it is processing and starts a new frame. This bit is a self−resetting bit and also returns to “0” during two−wire serial interface reads. Clocks The AR0130 requires one clock input (EXTCLK). PLL−Generated Master Clock The PLL contains a prescaler to divide the input clock applied on EXTCLK, a VCO to multiply the prescaler output, and two divider stages to generate the output clock. The clocking structure is shown in Figure 12. PLL control registers can be programmed to generate desired master clock frequency. NOTE: The PLL control registers must be programmed while the sensor is in the software Standby state. The effect of programming the PLL divisors while the sensor is in the streaming state is undefined. Figure 12. PLL−Generated Master Clock PLL Setup Pre PLL Div (PFD) Pre_pll_clk_div EXTCLK PLL Multiplier (VCO) PLL Output Div 1 SYSCLK PIXCLK vt_pix_clk_div vt_sys_clk_div PLL Input Clock PLL Output Clock PLL Output Div 2 pll_multiplier The PLL is enabled by default on the AR0130. To Configure and Use the PLL: 1. Bring the AR0130 up as normal; make sure that fEXTCLK is between 6 and 50MHz and ensure the sensor is in software standby (R0x301A[2]= 0). PLL control registers must be set in software standby. 2. Set pll_multiplier, pre_pll_clk_div, vt_sys_clk_div, and vt_pix_clk_div based on the desired input (fEXTCLK) and output (fPIXCLK) frequencies. Determine the M, N, P1, and P2 values to achieve the desired fPIXCLK using this formula: fPIXCLK= (fEXTCLK × M) / (N × P1 x P2) where M = PLL_Multiplier (R0x3030) N = Pre_PLL_Clk_Div (R0x302E) P1 = Vt_Sys_Clk_Div (R0x302C) P2 = Vt_PIX_Clk_Div (R0x302A) 3. Wait 1 ms to ensure that the VCO has locked. 4. Set R0x301A[2]=1 to enable streaming and to switch from EXTCLK to the PLL−generated clock. NOTES: 1. The PLL can be bypassed at any time (sensor will run directly off EXTCLK) by setting R0x30B0[14]=1. However, only the parallel data interface is supported with the PLL bypassed. The PLL is always bypassed in software standby mode. To disable the PLL, the sensor must be in standby mode (R0x301A[2] = 0) 2. The following restrictions apply to the PLL tuning parameters: 32 ≤ M ≤ 255 1 ≤ N ≤ 63 1 ≤ P1 ≤ 16 4 ≤ P2 ≤ 16 Additionally, the VCO frequency, defined as fVCO = fEXTCLK × M / N must be within 384 −768 MHz and the EXTCLK |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |