Back Button ADS131M08IPBSR Datasheet HTML 31Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 32Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 33Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 34Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 35Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 36Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 37Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 38Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 39Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 35 / 118 page
background image
consumption. Do not place a capacitor on the REFIN pin if current-detect mode is used. Capacitance on this pin
requires time to start up, and the resulting ADC conversions generated during current-detect mode are not valid
when the voltage on the REFIN pin is charging.
Current-detect mode is configured in the CFG, THRSHLD_MSB, and THRSHLD_LSB registers. Enable and
disable current-detect mode by toggling the CD_EN bit in the CFG register. The THRSHLD_MSB and
THRSHLD_LSB registers contain the CD_THRSH[23:0] bits that represent the digital comparator threshold
value during current detection.
The number of samples used for current detection are programmed by the CD_LEN[2:0] bits in the CFG register.
The number of samples used for current detection range from 128 to 3584.
The programmable values in CD_NUM[2:0] configure the number of samples that must exceed the threshold for
a detection to occur. The purpose of requiring multiple samples for detection is to control noisy values that may
exceed the threshold, but do not represent a high enough power level to warrant action by the host. In summary,
the conversion result must exceed the value programmed in CD_THRSH[23:0] a number of times as
represented by the value stored in CD_NUM[2:0].
The device can be configured to notify the host based on any of the results from either individual channels , all
channels, or any combination of channels. The CD_ALLCH bit in the CFG register determines how many
channels are required to exceed the programmed thresholds to trigger a current detection. When the bit is 1, all
enabled channels are required to meet the current detection requirements in order for the host to be notified. If
the bit is 0, any enabled channel triggers a current detection notification if the requirements are met. Enable and
disable channels using the CHn_EN bits in the CLK register to control which combination of channels must meet
the requirements to trigger a current-detection notification.
Figure 8-17 illustrates a flow chart depicting the current-detection process on the ADS131M08.
www.ti.com
ADS131M08
SBAS950B – OCTOBER 2019 – REVISED FEBRUARY 2021
Copyright © 2021 Texas Instruments Incorporated
Submit Document Feedback
35
Product Folder Links: ADS131M08



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com