Back Button ADS131M08IPBSR Datasheet HTML 95Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 96Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 97Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 98Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 99Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 100Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 101Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 102Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 103Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 99 / 118 page
background image
After the ADS131M08 registers are properly initialized, the MCU is configured to generate a GPIO interrupt
whenever a falling edge occurs on the DRDY pin, which indicates that the ADS131M08 has new samples
available.
The clock fed to the CLKIN pin of the ADS131M08 is internally divided by two to generate the modulator clock.
The output data rate of the ADS131M08 is therefore fMOD / OSR = fCLKIN / (2 × OSR) = 8 kSPS.
9.2.2.4 Calibration
Certain signal chain errors can be corrected through a single room temperature calibration. The ADS131M08
has the capability to store calibration values and use the values to correct the results in real time. Among those
errors that can be corrected in real time with the ADS131M08 are offset error, gain error, and phase error.
Offset calibration is performed by determining the measured output of the signal chain when the input is zero
voltage for a voltage channel or zero current for a current channel. The value can be measured and recorded in
external non-volatile memory for each channel. When the system is deployed, these values can be provided to
the CHn_OCAL_MSB and CHn_OCAL_LSB registers for the corresponding channels. The ADS131M08 then
subtracts these values from its conversion results prior to providing them to the host. Alternatively, the integrated
DC block filter can be used to implement offset correction.
Similar to offset error correction, system gain error can be determined prior to deployment and can be used to
correct the gain error on each channel in real time. Gain error is defined as the percentage difference in the ADC
transfer function from its PGA gain corrected ideal value of 1. This error can be determined by measuring the
results from both a maximum and minimum input signal, finding the difference between these results, and
dividing by the difference between the ideal difference. Equation 13 describes how to calculate gain error.
Max,Measured
Min,Measured
Max
Min
V,I
V,I
Gain Error
1
V,I
V,I
(13)
To correct for gain error, divide each offset-corrected conversion result by the measured gain. The ADS131M08
multiplies each conversion result by the calibration factor stored in the CHn_GCAL_MSB and CHn_GCAL_LSB
registers according to the method described in the Calibration Registers section. The host can program the
measured inverted gain values for each channel into these registers to have them automatically corrected for
each sample.
The ADS131M08 can also correct for system phase error introduced by sensors. For this design, the CT
introduces some phase error into the system. This design uses a software method for phase correction, but the
ADS131M08 can perform this function in real time. The system must first measure the phase relationships
between the various channels. Then, define one channel as phase 0. Subsequently, the PHASEn bits in the
CHn_CFG registers corresponding to the various other channels can be edited to correct their phase relationship
relative to the phase 0 channels.
9.2.2.5 Formulae
This section describes the formulas used for the power and energy calculations. Voltage and current samples
are obtained at a sampling rate of 8000 Hz. All samples that are taken in approximately one-second (1 sec)
frames are kept and used to obtain the RMS values for voltage and current for each phase.
Power and energy are calculated for active and reactive energy samples of one frame. These samples are
phase-corrected. Then phase active and reactive powers are calculated through the following formulas:
> @ > @
samples
N
1
Actual.ph
samples
n
0
1
P
v n
i n
N
u
¦
(14)
> @
samples
N
1
Re active.ph
90
samples
n
0
1
P
v n n
i n
N
ª
º u
¬
¼
¦
°
(15)
www.ti.com
ADS131M08
SBAS950B – OCTOBER 2019 – REVISED FEBRUARY 2021
Copyright © 2021 Texas Instruments Incorporated
Submit Document Feedback
99
Product Folder Links: ADS131M08



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com