ADS131M08IPBSR Datasheet(PDF) 100 Page - Texas Instruments

Part # ADS131M08IPBSR
Description  ADS131M08 8-Channel, Simultaneously-Sampling, 24-Bit, Delta-Sigma ADC
PDF  118 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI2 [Texas Instruments]
Direct Link  https://www.ti.com
Logo TI2 - Texas Instruments

ADS131M08IPBSR Datasheet(HTML) 100 Page - Texas Instruments

Back Button ADS131M08IPBSR Datasheet HTML 96Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 97Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 98Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 99Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 100Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 101Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 102Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 103Page - Texas Instruments ADS131M08IPBSR Datasheet HTML 104Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 100 / 118 page
background image
2
2
2
Apparent.ph
Actual.ph
Re active.ph
P
P
P
(16)
where:
• v[n] = Voltage sample
• i[n] = Current sample
• Nsamples = Number of samples in the approximately 1-second frame
• v[n-n90°] = Voltage sample with a 90° phase shift
• PACTUAL,ph = Instantaneous actual power for the measured phase
• PREACTIVE = Instantaneous reactive power for the measured phase
• PAPPARENT,ph = Instantaneous apparent power for the measured phase
The 90° phase shift approach is used for two reasons:
1. This approach allows accurate measurement of the reactive power for very small currents
2. This approach conforms to the measurement method specified by IEC and ANSI standards
The calculated mains frequency is used to calculate the 90° shifted voltage sample. Because the frequency of
the mains varies, the mains frequency is first measured accurately to phase shift the voltage samples
accordingly.
To get an exact 90° phase shift, interpolation is used between two samples. For these two samples, a voltage
sample slightly more than 90 degrees before the current sample and a voltage sample slightly less than 90°
before the current sample are used. The phase shift implementation of the application consists of an integer part
and a fractional part. The integer part is realized by providing an N samples delay. The fractional part is realized
by a one-tap FIR filter.
The cumulative power values can be calculated by summing the per phase power results. The cumulative
energy can be calculated by multiplying the cumulative power by the number of samples in the packet.
The host calculates the frequency in terms of samples-per-mains cycle by counting zero crossings of the sine
wave. Equation 17 converts this result from a samples-per-mains cycle to Hertz.
Frequency (Hz) = Data rate (samples / second) / Frequency (samples / cycle)
(17)
After the active power and apparent power are calculated, the absolute value of the power factor is calculated. In
the internal representation of power factor of the system, a positive power factor corresponds to a capacitive
load and a negative power factor corresponds to an inductive load. The sign of the internal representation of
power factor is determined by whether the current leads or lags voltage, which is determined in the background
process. Therefore, Equation 18 and Equation 19 calculate the internal representation of the power factor:
PF = PACTUAL / PAPPARENT, if capacitive load
(18)
PF = -PACTUAL / PAPPARENT, if inductive load
(19)
9.2.3 Application Curves
A source generator was used to provide the voltages and currents to the system. In this design, a nominal
voltage of 240 V between the line and neutral, a calibration current of 10 A, and a nominal frequency of 60 Hz
were used for each phase.
When the voltages and currents are applied to the system, the design outputs the cumulative active energy
pulses and cumulative reactive energy pulses at a rate of 6400 pulses per kilowatt hour. This pulse output was
fed into a reference meter that determined the energy percentage error based on the actual energy provided to
the system and the measured energy as determined by the active and reactive energy output pulse of the
system.
The current was varied from 50 mA to 100 A for the cumulative active energy error and cumulative reactive
energy error testing. A phase shift of 0°, 60°, and −60° was applied between the voltage and current waveforms
ADS131M08
SBAS950B – OCTOBER 2019 – REVISED FEBRUARY 2021
www.ti.com
100
Submit Document Feedback
Copyright © 2021 Texas Instruments Incorporated
Product Folder Links: ADS131M08



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com