| Electronic Components Datasheet Search |
|
AMC1301 Datasheet(PDF) 7 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AMC1301 Datasheet(HTML) 7 Page - Texas Instruments |
|
7 / 36 page ![]() 6.6 Insulation Specifications over operating ambient temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VALUE UNIT GENERAL CLR External clearance(1) Shortest pin-to-pin distance through air ≥ 8.5 mm CPG External creepage(1) Shortest pin-to-pin distance across the package surface ≥ 8.5 mm DTI Distance through insulation Minimum internal gap (internal clearance) of the double insulation ≥ 0.021 mm CTI Comparative tracking index DIN EN 60112 (VDE 0303-11); IEC 60112 ≥ 600 V Material group According to IEC 60664-1 I Overvoltage category per IEC 60664-1 Rated mains voltage ≤ 600 VRMS I-IV Rated mains voltage ≤ 1000 VRMS I-III DIN EN IEC 60747-17 (VDE 0884-17)(2) VIORM Maximum repetitive peak isolation voltage At AC voltage 1500 VPK VIOWM Maximum-rated isolation working voltage At AC voltage (sine wave) 1000 VRMS At DC voltage 1500 VDC VIOTM Maximum transient isolation voltage VTEST = VIOTM, t = 60 s (qualification test), VTEST = 1.2 × VIOTM, t = 1 s (100% production test) 7000 VPK VIMP Maximum impulse voltage(2) Tested in air, 1.2/50-µs waveform per IEC 62368-1 7700 VPK VIOSM Maximum surge isolation voltage(3) Tested in oil (qualification test), 1.2/50-µs waveform per IEC 62368-1 10000 VPK qpd Apparent charge((5)) Method a, after input/output safety test subgroups 2 and 3, Vpd(ini) = VIOTM, tini = 60 s, Vpd(m) = 1.2 × VIORM, tm = 10 s ≤ 5 pC Method a, after environmental tests subgroup 1, Vpd(ini) = VIOTM, tini = 60 s, Vpd(m) = 1.6 × VIORM, tm = 10 s ≤ 5 Method b1, at preconditioning (type test) and routine test, Vpd(ini) = 1.2 x VIOTM, tini = 1 s, Vpd(m) = 1.875 × VIORM, tm = 1 s ≤ 5 Method b2, at routine test (100% production)((7)), Vpd(ini) = Vpd(m) = 1.2 x VIOTM, tini = tm = 1 s ≤ 5 CIO Barrier capacitance, input to output(5) VIO = 0.5 VPP at 1 MHz ~1.2 pF RIO Insulation resistance, input to output(5) VIO = 500 V at TA = 25°C > 1012 Ω VIO = 500 V at 100°C ≤ TA ≤ 125°C > 1011 VIO = 500 V at TS = 150°C > 109 Pollution degree 2 Climatic category AMC1301 40/125/21 AMC1301S 55/125/21 UL1577 VISO Withstand isolation voltage VTEST = VISO, t = 60 s (qualification test), VTEST = 1.2 × VISO, t = 1 s (100% production test) 5000 VRMS (1) Apply creepage and clearance requirements according to the specific equipment isolation standards of an application. Care must be taken to maintain the creepage and clearance distance of a board design to ensure that the mounting pads of the isolator on the printed circuit board (PCB) do not reduce this distance. Creepage and clearance on a PCB become equal in certain cases. Techniques such as inserting grooves, ribs, or both on a PCB are used to help increase these specifications. (2) Testing is carried out in air to determine the surge immunity of the package. (3) Testing is carried in oil to determine the intrinsic surge immunity of the isolation barrier. (4) Apparent charge is electrical discharge caused by a partial discharge (pd). (5) All pins on each side of the barrier are tied together, creating a two-pin device. (6) Either method b1 or b2 is used in production. www.ti.com AMC1301 SBAS667G – APRIL 2016 – REVISED APRIL 2023 Copyright © 2023 Texas Instruments Incorporated Submit Document Feedback 7 Product Folder Links: AMC1301 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |