16 / 44 page ![]() CS5461A 16 DS661F2 INT pin will become active if the DRDY bit is unmasked in the Mask Register. When these bits are set, they must be cleared (logic 0) by the user before they can be asserted again. If the Cycle Count Register (N) is set to 1, all output cal- culations are instantaneous, and DRDY, like CRDY, will indicate when instantaneous measurements are fin- ished. Some calculations are inhibited when the cycle count is less than 2. 5.4 Energy Pulse Output The CS5461A provides three output pins for energy reg- istration. The E1 and E2 pins provide a simple interface which energy can be registered. These pins are de- signed to directly connect to a stepper motor or electro- mechanical counter. E1 and E2 pins can be set to one of four pulse output formats, Normal, Alternate, Stepper Motor, or Mechanical Counter. Table 2 defines the pulse output format, which is controlled by bits ALT in the Configuration Register, and MECH and STEP in the Control Register. The E3 pin is designated for system calibration, the pulse rate can be selected to reach a frequency of 512 kHz. The pulse output frequency of E1 and E2 is directly pro- portional to the active power calculated from the input signals. To calculate the output frequency on E1 and E2, the following transfer function can be utilized: With MCLK = 4.096 MHz, PF = 1, and default settings, the pulses will have an average frequency equal to the frequency setting in the PulseRateE1,2 Register when the input signals applied to the voltage and current channels cause full-scale readings in the instantaneous voltage and current registers. When MCLK/K is not equal to 4.096 MHz, the user should scale the PulseRateE1,2 Register by a factor of 4.096 MHz/(MCLK/K) to get the actual pulse rate out- put. 5.4.1 Normal Format The Normal format is the default. Figure 3 illustrates the output format on pins E1 and E2. The E1 pin outputs ac- tive-low pulses with a frequency proportional to the ac- tive power. The E2 pin is the energy direction indicator. Positive energy is represented by a pulse on the E1 pin while the E2 pin remains high. Negative energy is rep- resented by synchronous pulses on both the E1 pin and the E2 pin. The PulseRateE1,2 Register defines the average fre- quency on output pin E1, when full-scale input signals are applied to the voltage and current channels. The maximum pulse frequency from the E1 pin ALT STEP MECH FORMAT 000 Normal 0 X 1 Mechanical Counter 0 1 0 Stepper Motor 1 X 1 Alternate Pulse Table 2. E1 and E2 Pulse Output Format FREQE = Average frequency of E1 and E2 pulses [Hz] VIN = rms voltage across VIN+ and VIN- [V] VGAIN = Voltage channel gain IIN = rms voltage across IIN+ and IIN- [V] IGAIN = Current channel gain PF = Power Factor PulseRateE1,2 = Maximum frequency on E1 and E2 [Hz] VREFIN = Voltage at VREFIN pin [V] FREQ E VIN VGAIN × IIN × IGAIN PF × PulseRateE 12 , × × VREFIN 2 ------------------------------------------------------------------------------------------------------------------------------------------------ = E1 P o s itiv e E nergy B u rs t N e g a tiv e E nergy B u rs t . . . . . . . . . . . . E2 t du r Figure 3. Normal Format on pulse outputs E1 and E2 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |