| Electronic Components Datasheet Search |
|
ASBSERIES Datasheet(PDF) 14 Page - EPCOS |
|
|
|||||||||||||||||||||||||||||
ASBSERIES Datasheet(HTML) 14 Page - EPCOS |
|
14 / 16 page ![]() Pressure sensors Barometric pressure transmitters for SMT ASB series Preliminary data AS SEN PD 2011-05-02 Please read Cautions and warnings and Page 14 of 16 Important notes at the end of this document . Symbols and terms 1) Storage temperature range Tst A storage of the pressure sensor within the temperature range Tst,min up to Tst,max and without applied pressure and supply voltage will not affect the performance of the pressure sensor. 2) Operating temperature range Top An operation of the pressure sensor within the temperature range Top,min up to Top,max will not affect the performance of the pressure sensor. 3) Compensated temperature range Tc While operating the pressure sensor within the temperature range Tc,min up to Tc,max, the deviation of the output signal from the values at 25 °C will not exceed the temperature coefficients. Out of the compensated temperature range, the deviations may increase. 4) Rated pressure pr Within the rated pressure range 0 up to pr,max the signal output characteristic corresponds to this specification. 5) Overpressure pOV Pressure cycles within the pressure range 0 up to pov will not affect the performance of the pressure sensor. 6) Supply voltage Vsupply Vsupply,max is the maximum permissible supply voltage, which can be applied without damages. Vsupply,min is the minimum required supply voltage, which has to be applied for normal operation. 7) Signal output current IA IA,max is the maximum permissible sink current of the signal output. Exceeding (e.g. short circuit) may cause irreparable damages. 8) Start up time tSTA Time between the start up of the normal operation after power on and the first valid output signal. 9) Offset Vout,0 The offset Vout,0 is the signal output VA(p = 0) at zero pressure. 10) Signal span (Full Scale) Simple output: VFS = FS = Vout(pr,max) – VA0 11) Non-linearity L (including pressure hysteresis) The non-linearity is the deviation of the real sensor characteristic VA = f(p) from the ideal straight line. It can be approximated by a polynomial of second order, with the maximum at px = pr / 2 . The equation to calculate the non-linearity is: r x out r out out x out p p V p V V p V L − − − = 0 , 0 , ) ( ) ( 12) Response time t 10-90 Delay between a pressure change (10 ... 90% pr) and the corresponding signal output change (10 ... 90% FS). 13) Resolution r OUT The resolution of the output DAC (digital/analog converter). For ratiometric output only 80% of DAC range is used. |
|
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |