| Electronic Components Datasheet Search |
|
ZSC31010CEC Datasheet(PDF) 33 Page - Integrated Device Technology |
|
|
|||||||||||||||||||||||||||||
ZSC31010CEC Datasheet(HTML) 33 Page - Integrated Device Technology |
|
33 / 43 page ![]() ZSC31010 Datasheet © 2016 Integrated Device Technology, Inc. 33 January 20, 2016 3.6.2.7. SOT Interpretation SOT is a 2 nd order term that can apply to one and only one of the following: bridge non-linearity correction, Tco non-linearity correction, or Tcg non-linearity correction. As it applies to bridge non-linearity correction: Resolution: 0.25% @ Full Scale 2 nd order correction SOT_BR is possible up to +5%/-6.2% full scale difference from the ideal fit (straight line), because the SOT coefficient values are limited to the range of (0xC0 = -0.25dec) to (0x7F = 0.4960938dec). (Saturation in internal arithmetic will occur at greater negative non-linearities.) Limitation: Using any calibration method for which SOT is applied to the bridge measurement (SOT_BR), there is a possibility of calibration math overflow. This only occurs if the sensor input exceeds 200% of the calibrated full span, which means the highest applied sensor input should never go higher than this value. Example: This example of the limitation when SOT is applied to the bridge reading uses a pressure sensor bridge that outputs -10 mV at the lowest pressure of interest. That point is calibrated to read 0%. The same sensor outputs +40 mV at the highest pressure of interest. That point is calibrated to read 100%. This sensor has a 50 mV span over the pressure range of interest. If the sensor were to experience an over-pressure event that took the sensor output up to 90 mV (200% of span), the internal calculations could overflow. The result would be a corrected bridge reading that would not be saturated at 100% as expected, but instead read a value lower than 100%. This problem only occurs when SOT is applied to correct the bridge reading. As SOT applies to Tcg: Resolution: 0.3 ppm/( oC)2 Range: ±38 ppm/( oC)2 As it applies to Tco: Two settings are possible. It is possible to scale the effect of SOT by 8. If Tc_cfg[1] is set, then both, Tco and SOT’s contribution to Tco, are multiplied by 8. Resolution at unity scaling: 1.51 nV/V/( oC)2 (input referred) Range: ±0.192 mV/V/(oC)2 (input referred) Resolution at 8x scaling: 12.1 nV/V/( oC)2 (input referred) Range: ±1.54 mV/V/(oC)2 (input referred) Limitation: If the second order term SOT applies to Tco, the bridge gain Gain_B is limited to values equal or less than 8 (instead of 64). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |