| Electronic Components Datasheet Search |
|
ADP5360ACBZ-1-R7 Datasheet(PDF) 21 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADP5360ACBZ-1-R7 Datasheet(HTML) 21 Page - Analog Devices |
|
21 / 60 page ![]() Data Sheet ADP5360 Rev. 0 | Page 21 of 60 Trickle Charge Mode Timer The duration of trickle charge mode is monitored to ensure that the battery revives from the deeply discharged state. If trickle charge mode runs for longer than tTRK without the cell voltage reaching VTRK_DEAD, a fault condition is assumed and charging stops. The battery isolation FET turns off, and VSYS is regulated to VSYS_REG by the linear regulator. The fault condition asserts on when the CHARGER_STATUS[2:0] bits are set to 0b110, allowing the user to initiate the fault recovery procedure specified in the Fault Recovery section. Weak Charge Mode (Constant Current) When the battery voltage exceeds VTRK_DEAD but is less than VWEAK, the charger switches to the weak charge mode, and VSYS is regulated to VSYS_REG by the battery isolation FET. Note that, VSYSTEM = 5 V is not active on the output of VSYS_REG during charge mode. During weak charge mode, the battery is charged with programmed ICHG from VSYS through the isolation FET and ITRK_DEAD. Due to the VBUS input current limit, the real charge current (ICHG) from VSYS may be less than the programmed value. System load can share the current from VSYS. However, ITRK_DEAD always charges the battery during weak charge mode. Fast Charge Mode (Constant Current) When the battery voltage exceeds VWEAK, the charger switches to fast charge mode, charging the battery with ICHG. Address 0x04, ICHG[4:0] programs ICHG via the I2C interface. During fast charge mode (constant current), the CHARGER_STATUS[2:0] bits are set to 0b010. The default ICHG value can be set by the external resistor from the ICS pin (RICS) to ground. Floating the ICS pin activates the register default value when powering up. Table 12. Charge Current Default Set Using the ICS Pin RICS Value (kΩ) ICHG Value (mA) 100 10 68 50 47 80 36 100 27 150 20 200 15 250 10 300 During constant current mode, other features can prevent ICHG from reaching the full programmed value. Input current limiting for USB compatibility can affect the ICHG value under certain operating conditions. The battery isolation FET regulates VVSYS to stay at VSYS_REG. Note that, VSYSTEM = 5 V is not active on the output of VSYS_REG during charge mode. The ADP5360 features a dynamic charge current that is adaptive when VVBUS drops too much due to possible high internal impedance. The dynamic charge current monitors VVBUS and reduces the charge current level when VVBUS falls lower than the threshold, which can be programed by the I2C interface. When the charge current adapts due to the VVBUS level, the ADPICHG status bit is set high. By default, this feature is disabled and can be enabled by the I2C setting. Fast Charge Mode (Constant Voltage) As the battery charges, the voltage rises and approaches VTRM. The ADP5360 charger monitors VBSNS to determine when charging ends. However, the internal impedance of the battery pack combined with the PCB and other parasitic series resistances creates a voltage drop between the sense point at the BSNS pin and the cell terminal. To compensate for this voltage drop and ensure a fully charged cell, the ADP5360 enters a constant voltage charge mode when VBSNS reaches the termination voltage. The ADP5360 reduces charge current gradually as the cell continues to charge, maintaining a voltage of VTRM on the BSNS pin. During constant voltage fast charge mode, the CHARGER_STATUS[2:0] bits are set to 0b011. Fast Charge Mode Timer The duration of fast charge mode is monitored to ensure that the battery is charging correctly. If the fast charge mode runs for longer than tCHG without VBSNS reaching VTRM, a fault condition is assumed, charging stops, the battery isolation FET turns off, and VSYS regulates to VSYS_REG by the linear regulator. A fault condition asserts on when the CHARGER_STATUS[2:0] bits are set to 0b110, allowing the user to initiate the fault recovery procedure specified in the Fault Recovery section. If the fast charge mode runs for longer than tCHG and the BSNS pin reaches VTRM but the charge current has not yet fallen lower than IEND, charging stops by turning off the battery isolation FET. Note that the linear regulator still works, and VSYS regulates to VSYS_REG. No fault condition is asserted in this circumstance, and the ADP5360 attains charge complete status. Safety Timer If the watchdog timer (see the Watchdog Timer section for more information) expires while in charger mode, the ADP5360 charger initiates tSAFE. Charging continues for a period of tSAFE, then stops by turning off the battery isolation FET and setting the CHARGER_STATUS[2:0] bits to 0b110. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |