| Electronic Components Datasheet Search |
|
SH79F3283P/032PR Datasheet(PDF) 96 Page - SINOWEALTH Electronic Ltd |
|
|
|||||||||||||||||||||||||||||
SH79F3283P/032PR Datasheet(HTML) 96 Page - SINOWEALTH Electronic Ltd |
|
96 / 144 page ![]() SH79F3283 96 Slave 1 Slave 2 SADDR 10100100 10100111 SADEN (bit = 0 will be ignored) 11111010 11111001 Given Address 10100x0x 10100xx1 Broadcast Address (SADDR or SADEN) 1111111x 11111111 The given address for slave 1 and 2 differs in the LSB. For slave 1, it is ignore LSB, while for slave 2 LSB is 1. Thus to communicate only with slave 1, the master must send an address with LSB = 0 (10100000). Similarly the bit 1 is 0 for slave 1 and ignores the bit 1 for slave 2. Hence to communicate only with slave 2, the master has to transmit an address with bit 1 = 1 (1010 0011). If the master wishes to communicate with both slaves simultaneously, then the address must have bit 0 = 1 and bit 1 = 0. The bit 2 position is ignored for both the slaves. This allows two different addresses to select both slaves (1010 0001 and 1010 0101). The master can communicate with all the slaves simultaneously with the Broadcast Address. This address is formed from the logical OR of the SADDR and SADEN. The zeros in the result are defined as neglect. In most cases, the Broadcast Address is FFh, this address will be responded by all slaves. On reset, the SADDR and SADEN are initialized to 00h. The two results set Given Address and Broadcast Address to XXXXXXXX (all bits are ignored). This effectively removes the multiprocessor communications feature, since any selectivity is disabled. This ensures that the EUART will reply to any address, which it is compatible with the 80C51 microcontrollers that do not support automatic address recognition. So the user may implement multiprocessor communication by software recognition address according to the above mentioned method. Frame Error Detection Frame error detection is available when the SSTAT bit in register PCON is set to logic 1.All the 3 error falg bits should be cleared by software after they are set, even when the following frames received without any error will not be cleared automatically. Note: The SSTAT bit must be logic 1 to access any of the status bits (FE, RXOV, and TXCOL). The SSTAT bit must be logic 0 to access the Mode Select bits (SM0, SM1, and SM2). Transmit Collision The Transmit Collision bit (TXCOL bit in register SCON) set ‘1’ when a transmission is still in progress and user software writes data to the SBUF register. If collision occurs, the new data will be ignored and the transmit buffer will not be written. Receive Overflow The Receive Overflow bit (RXOV in register SCON) set ‘1’ if a new data byte is latched into the receive buffer before software has read the previous byte. The previous data is lost when this happen. Frame Error The Frame Error bit (FE in register SCON) set ‘1’ if an invalid (low) STOP bit is detected. Break Detection A break is detected when any 11 consecutive bits are detected as low. Since a break condition also satisfies the requirements for a framing error, a break condition will also result in reporting a framing error. Once a break condition has been detected, the UART will go into an idle state and remain in this idle state until a valid stop bit (rising edge on RxD pin) has been received. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |