| Electronic Components Datasheet Search |
|
AT87C5103-ICSIL Datasheet(PDF) 19 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
AT87C5103-ICSIL Datasheet(HTML) 19 Page - ATMEL Corporation |
|
19 / 64 page ![]() 19 AT8xC5103 4134C–8051–09/04 Slave Select (SS) Each Slave peripheral is selected by one Slave Select pin (SS). This signal must stay low for any message for a Slave. It is obvious that only one Master (SS high level) can drive the network. The Master may select each Slave device by software through port pins (Figure 8). To prevent bus conflicts on the MISO line, only one slave should be selected at a time by the Master for a transmission. In a Master configuration, the SS line can be used in conjunction with the MODF flag in the SPI Status register (SPSTA) to prevent multiple masters from driving MOSI and SCK (See Error Conditions). A high level on the SS pin puts the MISO line of a Slave SPI in a high-impedance state. The SS pin could be used as a general purpose if the following conditions are met: • The device is configured as a Master and the SSDIS control bit in SPCON is set. This kind of configuration can be found when only one Master is driving the network and there is no way that the SS pin will be pulled low. Therefore, the MODF flag in the SPSTA will never be set (1). • The Device is configured as a Slave with CPHA and SSDIS control bits set (2). This kind of configuration can happen when the system comprises one Master and one Slave only. Therefore, the device should always be selected and there is no reason that the Master uses the SS pin to select the communicating Slave device. Baud Rate In Master Mode, the baud rate can be selected from a baud rate generator which is con- trolled by three bits in the SPCON register: SPR2, SPR1 and SPR0. The Master clock is chosen from one of six clock rates resulting from the division of the internal clock by 4, 8, 16, 32, 64 or 128. Table 9 gives the different clock rates selected by SPR2:SPR1:SPR0: 1. Clearing SSDIS control bit does not clear MODF. 2. Special care should be taken not to set SSDIS control bit when CPHA = “0” because in this mode, the SS is used to start the transmission. Table 9. SPI Master Baud Rate Selection SPR2:SPR1:SPR0 Clock Rate Baud Rate Divisor (BD) 000 Don’t Use No BRG 001 FCLK_PERIPH /4 4 010 FCLK_PERIPH/8 8 011 FCLK_PERIPH /16 16 100 FCLK_PERIPH /32 32 101 FCLK_PERIPH /64 64 110 FCLK_PERIPH /128 128 111 Don’t Use No BRG |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |