AD4080BBCZ Datasheet(PDF) 39 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD4080BBCZ Datasheet(HTML) 39 Page - Analog Devices |
|
39 / 94 page ![]() Data Sheet AD4080 DIGITAL INTERFACE analog.com Rev. A | 39 of 94 Table 16. Device Status Data Sent Through the SDO in Long Instruction Mode (SHORT_INSTRUCTION = 0) (Continued) Bit Name Description 3 CRC_ERR Interface Status A Register Bit 3: CRC Error. This bit is set when the SPI controller does not send a CRC value or when the CRC value calculated by the device does not match the value received from the SPI controller. 2 WR_TO_RD_ONLY_REG_ERR Interface Status A Register Bit 2: Write to Read Only Register Error. Write to Read Only Register Attempted. This bit is set when the user attempts a write to a register that is read-only. 1 REGISTER_PARTIAL_ ACCESS_ERR Interface Status A Register Bit 1: Register Partial Access Error. This bit is set when a fewer than expected number of bytes are read from or written to in a multibyte register access. This bit is only valid when strict register access is enabled. 0 ADDRESS_INVALID_ERR Interface Status A Register Bit 0: Invalid Address Error. Attempt to read or write nonexistent register address. This bit is set when the user tries to access register addresses outside the allowed memory map space. Table 17. Device Status Data Sent Through the SDO in Short Instruction Mode (SHORT_INSTRUCTION = 1) Bit Name Description 7 Not applicable Bit 7 is always 0. 6 POR_FLAG Device Status Register Bit 0: POR Status. Allows user to detect when a POR event has occurred. A POR is triggered at power-up or when the logic supply drops to less than some threshold value or when the user issues a software reset. 0: POR Flag Cleared. 1: POR Event Detected. 5 NOT_READY_ERR Interface Status A Register Bit 7: Device Not Ready For Transaction Error. This bit is set if the user attempts to execute an SPI transaction before the completion of digital initialization. 4 CLOCK_COUNT_ERR Interface Status A Register Bit 4: Clock Count Error. This bit is set when an incorrect number of clocks is detected in a transaction. 3 CRC_ERR Interface Status A Register Bit 3: CRC Error. This bit is set when the SPI controller does not send a CRC, or when the CRC value calculated by the device does not match the value sent by the SPI controller. 2 WR_TO_RD_ONLY_REG_ERR Interface Status A Register Bit 2: Write To Read-only Register Error. This bit is set when the user attempts a write to a register that is read only. 1 REGISTER_PARTIAL_ ACCESS_ERR Interface Status A Register Bit 1: Register Partial Access Error. This bit is set when a fewer than expected number of bytes are read from or written to in a multibyte register access. This bit is only valid when strict register access is enabled. 0 ADDRESS_INVALID_ERR Interface Status A Register Bit 0: Invalid Address Error. This bit is set when the user tries to read from or write to a register address outside the allowed memory map space. Configuration Cyclical Redundancy Check (CRC) The AD4080 includes optional configuration error detection based on an 8-bit cyclical redundancy check algorithm. When enabled, an 8-bit checksum is inserted into the serial data output stream (SDO) during the data phase after each complete register transaction. De- pending on the register access type,that is, read or write, the host is expected to conditionally provide a corresponding checksum to the SDI immediately following each register access. The interface controller uses the host supplied checksum to determine if a CRC error has occurred. A mismatch in the checksum values computed by the host and the AD4080 interface results in setting the CRC_ERR flag (CRC_ERR = 1) in the Interface Status A register (see the Interface Status A Register section, Address 0x11). During a write access, a CRC error invalidates the most recent register data as well as any sub- sequent register data writes if in streaming mode (SINGLE_INST = 0), which prevents loading any potentially corrupted data into the configuration memory. In response to a CRC event, the host controller is required to initiate a new SPI frame to retry configura- tion of the effected memory locations. In the event the CRC_ERR is detected during a data read, the host controller must discard the received data and retry the data read in a new SPI frame. Clear the CRC_ERR flag before any attempt to initiate a repeated read or write to the configuration memory to allow detection of any subsequent errors. The error flag is cleared by writing code 0x08 to the Interface Status A register to set the CRC_ERR bit to a Logic 1. It is recommended that an immediate read of the Interface Status A register follows any attempt to clear the fault to validate the attempt was successful. The configuration CRC function is disabled by default and can be enabled through two complementary bit fields, CRC_ENABLE and CRC_ENABLEB, in the Interface Configuration C register (see the Interface Configuration C Register section, Address 0x10). To enable the CRC function, set the CRC_ENABLE bits to 1 and the CRC_ENABLEB bits to 10. Each of the complementary CRC bit fields is 2-bit wide, and any combination other than that specified results in the function remaining disabled. It is important to note that once the CRC function is enabled, a valid checksum from |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |