Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.NET

X  

UCC24612-2DBVT Datasheet(PDF) 20 Page - Texas Instruments

Part # UCC24612-2DBVT
Description  UCC24612 High Frequency Synchronous Rectifier Controller
PDF  38 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  TI2 [Texas Instruments]
Direct Link  https://www.ti.com
Logo TI2 - Texas Instruments

UCC24612-2DBVT Datasheet(HTML) 20 Page - Texas Instruments

Back Button UCC24612-2DBVT Datasheet HTML 16Page - Texas Instruments UCC24612-2DBVT Datasheet HTML 17Page - Texas Instruments UCC24612-2DBVT Datasheet HTML 18Page - Texas Instruments UCC24612-2DBVT Datasheet HTML 19Page - Texas Instruments UCC24612-2DBVT Datasheet HTML 20Page - Texas Instruments UCC24612-2DBVT Datasheet HTML 21Page - Texas Instruments UCC24612-2DBVT Datasheet HTML 22Page - Texas Instruments UCC24612-2DBVT Datasheet HTML 23Page - Texas Instruments UCC24612-2DBVT Datasheet HTML 24Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 20 / 38 page
background image
~~
~~
~~
~~
~~
~~
ISD
VDS
SR ON
TOFFBLANK
Clamp
Abs. Min
TRing
2.2TRing
20
UCC24612
SLUSCM5A – AUGUST 2017 – REVISED FEBRUARY 2018
www.ti.com
Submit Documentation Feedback
Copyright © 2017–2018, Texas Instruments Incorporated
Feature Description (continued)
Figure 21. Adaptive Off-Time Blanking with DCM Ring Clamp
For some conditions, as mentioned earlier, the off blanking timer suitable for DCM operation might be too long
for high-line QR operation. In this case, the off blanking timer clamp needs to be reset to the correct value.
UCC24612 continuously monitors the SR body diode conduction time during minimum off-time. If the body diode
conduction time is longer than the minimum on-time, this means the minimum off blanking time clamp setting is
too long and needs to be reduced. UCC24612 resets the minimum off blanking time clamp to the absolute
minimum of 400 ns to allow full conduction of the SR on the subsequent cycles.
If for any reason the off blanking time expires after the SR body diode conduction, the SR turn-on is skipped for
the switching cycle. This is because when the SR conducts, it conducts with a minimum on-time, if the blanking
time expires at the end of the SR conduction time and converter operates in the CCM condition, there is a good
chance to cause shoot-through and endanger the converter.
The off blanking time has a maximum value of tOFF_MAX at 3.68 µs.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com