Back Button SL13A-ASWB Datasheet HTML 14Page - ams AG SL13A-ASWB Datasheet HTML 15Page - ams AG SL13A-ASWB Datasheet HTML 16Page - ams AG SL13A-ASWB Datasheet HTML 17Page - ams AG SL13A-ASWB Datasheet HTML 18Page - ams AG SL13A-ASWB Datasheet HTML 19Page - ams AG SL13A-ASWB Datasheet HTML 20Page - ams AG SL13A-ASWB Datasheet HTML 21Page - ams AG SL13A-ASWB Datasheet HTML 22Page - ams AG Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 49 page
background image
SL13A – 18
ams Datasheet: 2014-May-06 [v1-01]
C o mmands
• Set External Calibration Data - #17
The SET-EXT-CAL-DATA command sets the user
calibration values. Those values have no effect on the
internal calibration settings.
Security level 1.
• Set Internal Calibration Data - #18
The SET-INT-CAL-DATA command sets the calibration
values for the internal temperature sensor.
Security level 1.
• Set Passive - #19
The SET-PASSIVE command stops the logging procedure
and returns the chip to passive mode. It also stops the
timer.
Security level 1.
• Start Log - #20
The START-LOG command starts the logging procedure
and sets the Start time in UTC format. In logging state the
chips automatically performs the measurements and data
logging in the specified time intervals. Supported is also
a delayed start, which means that the chip will start with
the logging procedure with a specified delay after it
receives the START-LOG command.
Security level 1.
• Get Log State - #21
The GET-LOG-STATE command gets the log state of
following parameters: measurement status and out of
limits counter. This gives the ability to quickly check the
state of the package without the need to read the whole
temperature data log.
•Get Calibration Data - #22
The GET-CALIBRATION command reads the calibration
data for the internal and external sensors.
• Get Battery Level - #23
The GET-BAT-LEVEL command measures and reads the
voltage level of the battery.
•Verify PW - #24
The VERIFY-PW command is used to verify the various
passwords.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com