29 / 61 page ![]() FDC2212, FDC2214, FDC2112, FDC2114 www.ti.com SNOSCZ5A – JUNE 2015 – REVISED JUNE 2015 Table 29. Address 0x12, SETTLECOUNT_CH1 Field Descriptions Bit Field Type Reset Description 15:0 CH1_SETTLECOUNT R/W 0000 0000 Channel 1 Conversion Settling 0000 0000 The FDC will use this settling time to allow the LC sensor to stabilize before initiation of a conversion on a Channel 1. If the amplitude has not settled prior to the conversion start, an Amplitude warning will be generated if reporting of this type of warning is enabled. b0000 0000 0000 0000: Settle Time (tS1)= 32 ÷ fREF1 b0000 0000 0000 0001: Settle Time (tS1)= 32 ÷ fREF1 b0000 0000 0000 0010 - b1111 1111 1111 1111: Settle Time (tS1)= (CH1_SETTLECOUNTˣ16) ÷ fREF1 9.6.20 Address 0x12, SETTLECOUNT_CH2 (FDC2114, FDC2214 only) Figure 37. Address 0x12, SETTLECOUNT_CH2 15 14 13 12 11 10 9 8 CH2_SETTLECOUNT 7 6 5 4 3 2 1 0 CH2_SETTLECOUNT Table 30. Address 0x12, SETTLECOUNT_CH2 Field Descriptions Bit Field Type Reset Description 15:0 CH2_SETTLECOUNT R/W 0000 0000 Channel 2 Conversion Settling 0000 0000 The FDC will use this settling time to allow the LC sensor to stabilize before initiation of a conversion on Channel 2. If the amplitude has not settled prior to the conversion start, an Amplitude warning will be generated if reporting of this type of warning is enabled. b0000 0000 0000 0000: Settle Time (tS2)= 32 ÷ fREF2 b0000 0000 0000 0001: Settle Time (tS2)= 32 ÷ fREF2 b0000 0000 0000 0010 - b1111 1111 1111 1111: Settle Time (tS2)= (CH2_SETTLECOUNTˣ16) ÷ fREF2 9.6.21 Address 0x13, SETTLECOUNT_CH3 (FDC2114, FDC2214 only) Figure 38. Address 0x13, SETTLECOUNT_CH3 15 14 13 12 11 10 9 8 CH3_SETTLECOUNT 7 6 5 4 3 2 1 0 CH3_SETTLECOUNT Table 31. Address 0x13, SETTLECOUNT_CH3 Field Descriptions Bit Field Type Reset Description 15:0 CH3_SETTLECOUNT R/W 0000 0000 Channel 3 Conversion Settling 0000 0000 The FDC will use this settling time to allow the LC sensor to stabilize before initiation of a conversion on Channel 3. If the amplitude has not settled prior to the conversion start, an Amplitude warning will be generated if reporting of this type of warning is enabled b0000 0000 0000 0000: Settle Time (tS3)= 32 ÷ fREF3 b0000 0000 0000 0001: Settle Time (tS3)= 32 ÷ fREF3 b0000 0000 0000 0010 - b1111 1111 1111 1111: Settle Time (tS3)= (CH3_SETTLECOUNTˣ16) ÷ fREF3 Copyright © 2015, Texas Instruments Incorporated Submit Documentation Feedback 29 Product Folder Links: FDC2212 FDC2214 FDC2112 FDC2114 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |