| Electronic Components Datasheet Search |
|
AD9923ABBCZ Datasheet(PDF) 38 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9923ABBCZ Datasheet(HTML) 38 Page - Analog Devices |
|
38 / 88 page ![]() AD9923A Rev. 0 | Page 38 of 88 MODE Register The MODE register is a single register that selects the field timing of the AD9923A. Typically, all field, V-sequence, and V-pattern group information is programmed into the AD9923A at startup. During operation, the MODE register allows the user to select any combination of field timing to meet the current requirements of the system. Using the MODE register in conjunction with preprogrammed timing greatly reduces the system programming requirements during camera operation. Only a few register writes are required when the camera operating mode is changed rather than having to rewrite the vertical timing information with each camera mode change. A basic still camera application can require five fields of vertical timing—one for draft mode operation, one for autofocusing, and three for still image readout. The register timing information for the five fields is loaded at startup. Depending on how the camera is being used, the MODE register selects which field timing is active during camera operation. Table 20 shows how the MODE register bits are used. Unlike other registers, the MODE register uses 10 address bits as data bits to increase the total register size to 38 bits. The address MSBs, A11 and A10, are 1 and 0, respectively, and are used to specify the MODE register write. The three MSBs, D37, D36, and D35 are used to specify the number of fields used. A value from 1 to 7 can be selected using these three bits. The remaining register bits are divided into five-bit sections to select which programmed fields are used and in which order. Up to seven fields can be used in a single MODE write. The AD9923A starts with the field timing specified by the first field bit, and switches to the timing specified by the second field bit on the next VD, and so on. After completing the number of fields specified in Bit D37 to Bit D35, the timing generator of the AD9923A repeats itself by starting at the first field. This continues until a new write to the MODE register occurs. Figure 51 shows MODE register settings for various field configurations. Table 20. Mode Register Contents—VD Updated Address (Binary) Data Bits Default Value Description 12b10_xx_xxxx_xxxx [37:0] 0 A11, A10 must be set to 0x10; remaining A9:A0 bits used for D37:D28 [37:35] Number of fields (maximum of seven) [34:30] Selected field for Field 7 [29:25] Selected field for Field 5 [24:20] Selected field for Field 6 [19:15] Selected field for Field 4 [14:10] Selected field for Field 3 [9:5] Selected field for Field 2 [4:0] Selected field for Field 1 EXAMPLE 1: TOTAL FIELDS = 3, FIRST FIELD = FIELD 0, SECOND FIELD = FIELD 1, THIRD FIELD = FIELD 2 MODE REGISTER CONTENTS = 0x9800000820 EXAMPLE 2: TOTAL FIELDS = 1, FIRST FIELD = FIELD 3 MODE REGISTER CONTENTS = 0x8800000003 EXAMPLE 3: TOTAL FIELDS = 4, FIRST FIELD = FIELD 5, SECOND FIELD = FIELD 1, THIRD FIELD = FIELD 4, FOURTH FIELD = FIELD 2 MODE REGISTER CONTENTS = 0xA000011025 FIELD 3 FIELD 0 FIELD 1 FIELD 2 FIELD 5 FIELD 1 FIELD 4 FIELD 2 Figure 51. Using the Mode Register to Select Field Timing |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |