| Electronic Components Datasheet Search |
|
GL843 Datasheet(PDF) 46 Page - GENESYS LOGIC |
|
|
|||||||||||||||||||||||||||||
GL843 Datasheet(HTML) 46 Page - GENESYS LOGIC |
|
46 / 84 page ![]() GL843 High Speed USB2.0 With ADF 2-in-1 Scanner Controller For 3x ©2000-2006 Genesys Logic Inc. - All rights reserved. Page 46 7-0 HISPD[7:0] To change of the speed of motor during moving Note: It cannot be programmed to logic zero. Offset 5Eh ……..……..………………..………..….………..….…..…..…..…. Default value = 8’h00 DECSEL2 DECSEL1 DECSEL0 STOPTIM4 STOPTIM3 STOPTIM2 STOPTIM1 STOPTIM0 R/W R/W R/W R/W R/W R/W R/W R/W 7-5 DECSEL[2:0] Deceleration steps number after touching home sensor. 000 1 steps deceleration 001 2 steps deceleration 010 4 steps deceleration 011 8 steps deceleration 100 16 steps deceleration 101 32 steps deceleration 110 64 steps deceleration 111 128 steps deceleration 4-0 STOPTIM[4:0] Stop time between forward and backward direction in backtracking. Note: In ASIC simulation process, STOPTIM has to be set to tgtime=6,7. It cannot be programmed to logic zero. Offset 5Fh ……..………………………..………..….………..….…..…..…..…. Default value = 8’h00 FMOVDEC7 FMOVDEC6 FMOVDEC5 FMOVDEC4 FMOVDEC3 FMOVDEC2 FMOVDEC1 FMOVDEC0 R/W R/W R/W R/W R/W R/W R/W R/W 7-0 FMOVDEC[7:0] Deceleration steps in table 5 for auto-go-home. Note: 1.It cannot be programmed to logic zero. 2.It can be multiplied by 2 * STEPTIM Offset 60h ……..………………………..………..….………..….…..…..…..…. Default value = 8’h00 X X X Z1MOD20 Z1MOD19 Z1MOD18 Z1MOD17 Z1MOD16 X X X R/W R/W R/W R/W R/W 7-5 RESERVED - 4-0 Z1MOD[20:16] “remainder value” of MOD operation in acceleration/deceleration tables. ASIC calculate the moving time by MOD operation when buffer-full occurs. Note: It should be less than LPERIOD. Offset 61h ……..………………………..………..….………..….…..…..…..…. Default value = 8’h00 Z1MOD15 Z1MOD14 Z1MOD13 Z1MOD12 Z1MOD11 Z1MOD10 Z1MOD7 Z1MOD8 R/W R/W R/W R/W R/W R/W R/W R/W 7-0 Z1MOD[15:8] “remainder value” of MOD operation in acceleration/deceleration tables. ASIC calculate the moving time by MOD operation when buffer-full occurs. Note: It should be less than LPERIOD. Offset 62h ……..………………………..………..….………..….…..…..…..…. Default value = 8’h00 Z1MOD7 Z1MOD6 Z1MOD5 Z1MOD4 Z1MOD3 Z1MOD2 Z1MOD1 Z1MOD0 R/W R/W R/W R/W R/W R/W R/W R/W |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |