796 / 1386 page ![]() SCC Ethernet Mode MPC8280 PowerQUICC II Family Reference Manual, Rev. 1 25-8 Freescale Semiconductor 0x4C MINFLR Hword Minimum frame length register. The Ethernet controller checks the incoming frame’s length against MINFLR (typically 64 decimal). If the received frame is smaller than MINFLR, it is discarded unless PSMR[RSH] is set, in which case, SH is set in the last BD for the frame. For transmitting a frame that is too short, the Ethernet controller pads the frame to make it MINFLR bytes long, depending on how PAD is set in the TxBD and on the PAD value in the parameter RAM. 0x4E MAXD1 Hword Max DMA n length register. Gives the option to stop system bus writes after a frame exceeds a certain size. However, this value is valid only if an address match is found. The Ethernet controller checks the length of an incoming Ethernet frame against this user-defined value (usually 1520 decimal). If this limit is exceeded, the rest of the incoming frame is discarded. The Ethernet controller waits until the end of the frame or until MFLR bytes are received and reports the frame status and the frame length in the last RxBD. MAXD1 is used when an address matches an individual or group address. MAXD2 is used in promiscuous mode when no address match is detected. In a monitor station, MAXD2 can be much less than MAXD1 to receive entire frames addressed to this station, but only the headers of the other frames are received. 0x50 MAXD2 Hword 0x52 MAXD Hword Rx max DMA. 0x54 DMA_CNT Hword Rx DMA counter. A temporary down-counter used to track frame length. 0x56 MAX_B Hword Maximum BD byte count. 0x58 GADDR1 Hword Group address filter 1–4. Used in the hash table function of the group addressing mode. Write zeros to these values after reset and before the Ethernet channel is enabled to disable all group hash address recognition functions. The SET GROUP ADDRESS command is used to enable the hash table. 0x5A GADDR2 0x5C GADDR3 0x5E GADDR4 0x60 TBUF0_DATA0 Word Save area 0—current frame. 0x64 TBUF0_DATA1 Word Save area 1—current frame. 0x68 TBUF0_RBA0 Word 0x6C TBUF0_CRC Word 0x70 TBUF0_BCNT Hword 0x72 PADDR1_H Hword The 48-bit individual address of this station into this location. PADDR1_L is the lowest order hword and PADDR1_H is the highest order hword. 0x74 PADDR1_M 0x76 PADDR1_L 0x78 P_PER Hword Persistence. Lets the Ethernet controller be less aggressive after a collision. Normally, 0x0000. It can be a value between 1 and 9 (1 is most aggressive). The value is added to the retry count in the backoff algorithm to reduce the chance of transmission on the next time slot. Note: Using P_PER is fully allowed in the Ethernet/802.3 specifications. A less aggressive backoff algorithm used by multiple stations on a congested Ethernet LAN increases overall throughput by reducing the chance of collision. PSMR[SBT] offers another way to reduce the aggressiveness of the Ethernet controller. 0x7A RFBD_PTR Hword Rx first BD pointer. Table 25-1. SCC Ethernet Parameter RAM Memory Map (continued) Offset 1 Name Width Description |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |