24 / 67 page ![]() ADT7476 http://onsemi.com 24 Figure 32. Understanding the THERM Timer THERM THERM TIMER (REG. 0x79) THERM ASSERTED v 22.76ms 765 321 0 4 000 000 1 0 THERM TIMER (REG. 0x79) THERM ASSERTED w 45.52ms 765 321 0 4 000 001 0 0 THERM TIMER (REG. 0x79) THERM ASSERTED w 113.8ms (91.04ms + 22.76ms) 765 321 0 4 000 010 1 0 THERM ACCUMULATE THERM LOW ASSERTION TIMES THERM ACCUMULATE THERM LOW ASSERTION TIMES When using the THERM timer, be aware of the following: After a THERM timer read (0x79) 1. The contents of the timer are cleared on read. 2. The F4P bit (Bit 5) of Interrupt Status Register 2 needs to be cleared (assuming that the THERM timer limit has been exceeded). If the THERM timer is read during a THERM assertion, the following occurs: 1. The contents of the timer are cleared. 2. Bit 0 of the THERM timer is set to 1, because a THERM assertion is occurring. 3. The THERM timer increments from zero. 4. If the THERM timer limit register (0x7A) = 0x00, the F4P bit is set. Generating SMBALERT Interrupts from THERM Timer Events The ADT7476 can generate SMBALERTs when a programmable THERM timer limit has been exceeded. This allows the system designer to ignore brief, infrequent THERM assertions, while capturing longer THERM timer events. Register 0x7A is the THERM timer limit register. This 8−bit register allows a limit from 0 sec (first THERM assertion) to 5.825 sec to be set before an SMBALERT is generated. The THERM timer value is compared with the contents of the THERM timer limit register. If the THERM timer value exceeds the THERM timer limit value, then the F4P bit (Bit 5) of Interrupt Status Register 2 is set and an SMBALERT is generated. Note: Depending on which pins are configured as a THERM timer, setting the F4P bit (Bit 5) of Mask Register 2 (0x75) or Bit 0 of Mask Register 1 (0x74) masks out SMBALERT; although the F4P bit of Interrupt Status Register 2 is still set if the THERM timer limit is exceeded. Figure 33 is a functional block diagram of the THERM timer, limit, and associated circuitry. Writing a value of 0x00 to the THERM timer limit register (0x7A) causes an SMBALERT to be generated on the first THERM assertion. A THERM timer limit value of 0x01 generates an SMBALERT once cumulative THERM assertions exceed 45.52 ms. Figure 33. Functional Block Diagram of THERM Monitoring Circuitry 22.76ms 45.52ms 91.04ms 182.08ms 364.16ms 728.32ms 1.457s 2.914s IN OUT RESET LATCH CLEARED ON READ F4P BIT (BIT 5) MASK REGISTER 2 (REG. 0x75) 1 = MASK F4P BIT (BIT 5) STATUS REGISTER 2 COMPARATOR 22.76ms 45.52ms 91.04ms 182.08ms 364.16ms 728.32ms 1.457s 2.914s 7 6 5 4 3 2 1 0 7 6 543 2 1 0 THERM LIMIT (REG. 0x7A) THERM TIMER (REG. 0x79) THERM TIMER CLEARED ON READ SMBALERT THERM |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |