Back Button L9966 Datasheet HTML 65Page - STMicroelectronics L9966 Datasheet HTML 66Page - STMicroelectronics L9966 Datasheet HTML 67Page - STMicroelectronics L9966 Datasheet HTML 68Page - STMicroelectronics L9966 Datasheet HTML 69Page - STMicroelectronics L9966 Datasheet HTML 70Page - STMicroelectronics L9966 Datasheet HTML 71Page - STMicroelectronics L9966 Datasheet HTML 72Page - STMicroelectronics L9966 Datasheet HTML 73Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 69 / 122 page
background image
Once a new value is defined, new hysteresis threshold is applied after the second VRS_OUT HL transition and
until the next rising edge of the VRS input differential voltage occurs.
15.2.6
VRS_B –Limited Adaptive Hysteresis
To set the limited adaptive hysteresis on VRS_B configuration, bit VRS_CONF_MODE[0] has to be set to ‘1’.
In this mode, user programs a hysteresis threshold through VRS_HYST_CONF[2:0] bit in VRS register and the
internal logic selects a hysteresis based on input signal peak value (see Section 15.2.3 VRS_A – Fully adaptive
hysteresis): the maximum of these two values is actually applied.
Default hysteresis current after exiting reset is HI1.
Once a new value is defined, new hysteresis threshold is applied after the first or the second VRS_OUT HL
transition depending on LIM_ADAP_DOUBLE_EDGE bit in VRS register, if the bit has been fixed “0” the new
hysteresis value is applied after the first VRS_OUT HL transition (default), otherwise after the second.
Current hysteresis value is active until the next rising edge of the VRS input differential voltage occurs.
When VRS_B architecture is selected, it is possible to force the hysteresis current to its minimum value through
HYST_MIN_FORCE of VRS register regardless of the content of VRS_HYST_CONF [1,0] bit.
Default hysteresis current after exiting reset is HI1.
15.2.7
VRS_B – Fixed Filter Time
In VRS_B configuration, it is possible to enable the filter time on the output of the zero crossing comparator
through the bit VRS_CONF_MODE[1] of VRS register. This configuration allows defining the internal filter time at
a fixed value of 2.5 µs, active on both rising and falling edges of VRS output. The starting filter time period at
power on reset is 125 µs.
As per VRS_A architecture, VRS_FE_FLT_EN allows configuring the same two different strategies for the filtering
algorithm (see Section 15.2.4 VRS_A – Adaptive Filter Time).
15.3
VRS Diagnostic Mode
The diagnostic mode is selected through VRS_EN_DIAG = ‘1’ in VRS register. This mode provides feedback to
detect faulty conditions either on VRSP or VRSN.
To be noted that diagnostic results are not reliable while the flying wheel is rotating.
If a fault is detected in DIAG mode, VRS correct functionality is not guaranteed.
Based on three comparators, it is possible to detect an open load fault condition, a short to ground or a short to
battery fault condition. Fault bit VRS_FAULT[1:0] of VRS register are consequently set.
Once a fault has been detected being the diagnostic active (VRS_EN_DIAG=1) if the faulty condition is stable,
DIAG_CLEAR_CMD set does not clear VRS_FAULT[1:0] field; if the faulty condition is solved, a write SPI access
with DIAG_CLEAR_CMD=1 clears VRS_FAULT[1:0] field in terms of internal device register; only through another
SPI access (either write or read access) determines VRS_FAULT[1:0] reset in SPI VRS register.
Once a fault has been detected (VRS_EN_DIAG=1), the reset of VRS_FAULT[1:0] field because of the diagnostic
has been switched off, requires three SPI accesses:
•
The first one to switch off the diagnostic and any DIAG_CLEAR_CMD set in the same frame is ignored
•
Once the diagnostic is switched off, DIAG_CLEAR_CMD set determines the reset of VRS_FAULT[1:0] field
in the internal register;
•
The next SPI access (W or R) shows on SPI that VRS_FAULT[1:0] field in VRS register has been cleared
Figure 38. VRS block diagram - Diagnostic operating mode - Current path shows the circuit used in Diagnostic
mode.
When VRS diagnostic mode is activated, VRSP is fixed at Vcm_DIAG and IDIAG current generator is enabled ;
the current path is the one in yellow in Figure 38. VRS block diagram - Diagnostic operating mode - Current path.
L9966
VRS Diagnostic Mode
DS12459 - Rev 10
page 69/122



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com