| Electronic Components Datasheet Search |
|
M95P16-EXCS/EF Datasheet(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M95P16-EXCS/EF Datasheet(HTML) 13 Page - STMicroelectronics |
|
13 / 63 page ![]() In addition, the Chip select (S) input offers a built-in safety feature: its input is edge-sensitive as well as level ‑sensitive: after power-up, the device does not become selected until a falling edge has first been detected on it. This ensures that Chip select (S) must have been high, prior to going low to start the first operation. The VCC voltage must rise continuously, from 0 V up to the minimum VCC operating voltage defined in Table 18. Operating conditions. 4.7 Power-down conditions During power-down (continuous decrease of the supply voltage below the minimum VCC operating voltage defined in Table 18. Operating conditions), the device must be: • deselected (S must follow the voltage applied on VCC) • in standby power mode (there must not be any internal write cycle in progress). 4.8 Active power, Standby power and Deep power-down modes When Chip select (S) is low, the device is selected, and in Active power mode. When Chip select (S) is high, the device is deselected, but remains in Active power mode until all internal cycles have completed (Program, Erase, Write Status register). The device then goes into Standby power mode. The device consumption drops to ICC1 as specified in Table 23. DC characteristics - Current consumption - M95P16-I. Deep power-down mode is entered when the Deep power-down command is executed. The device consumption drops further to ICC2. The device remains in this mode until the Release from power-down command is executed. While in Deep power-down mode the device ignores all Write, Program and Erase commands. This provides an extra software protection mechanism when the device is not in active use, by protecting it from inadvertent operations. For further information, see Section 6.21 Deep power-down enter (B9h). 4.9 Device reset To prevent erroneous instruction decoding and inadvertent programming, write or erase operations during power ‑up, a power‑on‑reset (POR) circuit is included. At power-up, the device does not respond to any instruction until VCC reaches the POR threshold voltage. This threshold is lower than the minimum VCC operating voltage (see Table 18. Operating conditions). At power-up, when VCC passes over the POR threshold, the device is reset and is in the following state: • In Standby power mode • Deselected • Status register – Write enable latch (WEL) bit reset to 0 – Write In Progress (WIP) bit reset to 0 – All non volatile bits unchanged • Configurable and Safety register – All volatile bits reset to 0 – All non volatile bits unchanged • Volatile register – All bits reset to 0, except BUFLD, set to 1 The device must not be accessed until VCC reaches a valid and stable level, within the specified VCC(min) to VCC(max) range, defined in Table 18. Operating conditions. 4.10 Hold condition The Hold (HOLD) signal is used to pause serial communications with the device, without resetting the clocking sequence. However, setting this signal low does not terminate Write Status register, Program, Write, or Erase cycles that are in progress. To enter the Hold condition, the device must be selected with Chip select (S) low. During the Hold condition, the Serial data output (Q) is high-Z, and the Serial data input (D) and Serial clock (C) are Don’t care. M95P16-I M95P16-E Power-down conditions DS13710 - Rev 1 page 13/63 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |