35 / 48 page ![]() Yn = Yn-1 + (lpf_b0fns/65,536) x (Xn - Yn-1) Filter coefficient (lpf_b0fns) is a signed 16-bit value and can be configured by the master. In the previous equa- tion, Y denotes the global NS value, and X denotes individual NS measurements produced by zero-cross- ing events detected on phase A, B, or C voltage chan- nel. Note that if all three phase voltages are present, the filter above receives three inputs each line cycle. The global NS value is used to generate line-cycle trig- ger for DSP processing. Note that value NS can be configured by the master, which may be necessary if all three voltage signals are lost and no zero crossings are detected. The line period is then calculated as a product of NS and the scan slot period tC (stored in the timing calibration register TIME_FS). The reciprocal of this value is the line frequency, which can be obtained as a fixed-point value with 1 LSB = 0.001Hz by reading the virtual register LINEFREQ. No-Zero-Crossing Detection The MAXQ3180 monitors the voltage signal on each phase for zero-crossing events. If no ascending zero crossings are detected within a specified number of analog scan frame periods, the NOZC (STATUS1.11) flag is set by the MAXQ3180 to notify the master of this condition. If the interrupt enable bit INT_MASK.11 is set to 1, the interrupt signal IRQ is driven low by the MAXQ3180 whenever NOZC = 1. The master can clear NOZC back to 0 to remove the interrupt condition. Phase Sequence Errors A phase sequence error occurs when zero-crossing events occur on all three phases, but they do not occur in the expected order. Normally, a zero-crossing event should occur on the phase A voltage signal, followed by phase B, phase C, and then phase A again. If a zero crossing on phase A is then followed immediately by a zero crossing on phase C (and not by phase B as expected), this is registered by the MAXQ3180 as a phase sequence error. When a phase sequence error occurs, the MAXQ3180 sets the phase sequence error flag SEQERR (STATUS1.15) to 1. If the corresponding interrupt enable bit (INT_MASK.15) is also set to 1, the interrupt signal IRQ is driven low by the MAXQ3180 whenever SEQERR = 1. The master can clear SEQERR back to 0 to remove the interrupt condition. RMS Voltage, RMS Current, and Energy Calculation For each of the three phases, the MAXQ3180 calcu- lates RMS voltage and RMS current values, as well as determines active and reactive energy, using a line- cycle-based integration process. Power Calculation (Active, Reactive, Apparent) The power, energy, and RMS calculation process con- sists of two tasks: continuous accumulation and post- processing triggered every CYCNT line cycles. The accumulation task accumulates raw data obtained from the AFE during CYCNT line cycles. This task is per- formed continuously in the background by the MAXQ3180. When a CYCNT line cycles accumulation stage has completed, which is determined by a dedi- cated frame counter exceeding the CYCNT x NS level, the raw integral accumulator values are saved for post- processing and cleared, beginning the next cycle of accumulation task. Then, the DSP postprocessing is triggered to process saved integrals and calculate energy, power, etc., values. Note that the background accumulation task continues while foreground postpro- cessing is taking place, i.e., both tasks are executed simultaneously sharing CPU time. It is essential that the DSP postprocessing calculations be completed before the next DSP trigger to avoid losing accumulated data. The master should allow enough processing time by adjusting the R_ADCRATE register. Default settings provide plenty of CPU time for both tasks. The MAXQ3180 accumulates raw sums and calculates line-cycle integrals for each voltage-current pair sepa- rately. The individual power accumulators are: • P1 = (VA x IA) • P2 = (VB x IB) or -IB x (VA + VC) or -IB x VA • P3 = (VC x IC) The P1 and P3 accumulators always operate in a single mode: (VA x IA) for the P1 accumulator, (VC x IC) for the P3 accumulator. Alternately, the operating mode of the P2 accumulator is defined by setting bits 0 and 1 in the CONNCT register as shown in Table 8. If the CONNCT bits are set to 01b, then the P2 (phase B) input voltage sample is calculated using an allpass filter described as: (VA + VC)n = (AVCO/216)(VCn + VAn-1) + (AVC1/216)(VCn-1 + VAn) Low-Power, Multifunction, Polyphase AFE ______________________________________________________________________________________ 35 Table 8. P2 Power Accumulator Modes CONNCT[1:0] P2 OPERATING MODE WIRING CONFIGURATIONS 00b (VB x IB) 5S/13S 3-Wire Delta, 9S/16S 4-Wire Wye 01b -IB x (VA + VC) 6S/14S 4-Wire Wye 10b, 11b -IB x VA 8S/15S 4-Wire Delta |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |