20 / 40 page ![]() RUN REVW PRLO PRHI XXXX XXXX CAL PRLO PRHI XXXX XXXX ENT ENT ENT ENT ENT ENT ENT ENT ENT ENT 2.4.2 Program Path 3 — Probe Calibration NOTES: 1. The media level must be moved to accomplish this procedure. The PRLO and PRHI points may be entered in any order; they can easily be changed in the future when the process level is at a much higher or lower point. 2. The unit will automatically time out and revert to the RUN mode after 60 seconds without a keystroke; any information already entered remains in memory. To enter any remaining data, sim- ply re-enter the Probe Calibration section. 3. A minimum level change of 2% or 5pF, whichever is greater, of tank height will yield a valid calibration. However, a greater level change yields better accuracy. STEP 1: REVW (Review) This menu allows the review of any previously stored PRLO/PRHI points. If this is the first time calibration is performed, proceed to Step 2. 1. To enter this menu from the RUN mode, press the UP and DOWN arrow keys simultaneously. ( ) The display will read REVW (review). 2. Press ENT to display PRLO (probe low). 3. Press ENT to display the previously stored PRLO point. 4. Press ENT to display PRHI. 5. Press ENT to display the previously stored PRHI point. 6. Press ENT to display PRLO. 7. Press the DOWN arrow to return to the main path. The display will read CAL. NOTE: If re-entering new PRLO/PRHI points for better accuracy, be sure that the new PRLO point is lower than the existing PRLO point and the new PRHI point is higher than the existing PRHI point. STEP 2: CAL (Calibrate) This menu allows the calibration of the Probe. Caution: This is the most critical section of the calibration proce- dure. Before pressing ENT to enter data into the PRLO or PRHI areas, be sure it is the proper area needed at that point. If an improper area is entered, pressing all three but- tons simultaneously will return you to the RUN mode. 1. To enter this menu, press ENT . The display will read PRLO (probe low). ENT ENT ENT ENT ENT ENT ENT 50-621 Kotron Sentinel Models 822, 832 and 842 RF Point Level Switches 17 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |