18 / 52 page ![]() Sensors 18 Freescale Semiconductor, Inc. MMA685x 3.1.9 Arming Threshold Registers (ARMT_P, ARMT_N) These registers contain the positive and negative thresholds to be used by the arming function. Refer to Section 3.8.9 for more details regarding the arming function. These registers can be written during initialization but are locked once the ENDINIT bit is set. Refer to Section 3.1.6.2. These registers are included in the writable register CRC check. Refer to Section 3.2.2 for details. The values programmed into the threshold registers are the threshold values used for the arming function as described in Section 3.8.9. The threshold registers hold independent unsigned 8-bit values for polarity. Each threshold increment is equivalent to one output LSB. Table 18 shows examples of some threshold register values and the corresponding threshold. If either the positive or negative threshold is programmed to $00, comparisons are disabled for only that polarity. The arming function still operates for the opposite polarity. If both the positive and negative arming thresholds are programmed to $00, the Arming function is disabled, and the output pin is disabled, regardless of the value of the A_CFG bits in the DEVCFG register. 3.1.10 Device Status Register (DEVSTAT) The device status register is a read-only register. A read of this register clears the status flags affected by transient conditions. Reference Section 4.5 for details on the MMA685x response for each status condition. 3.1.10.1 Unused Bit (UNUSED) The unused bit has no impact on operation or performance. When read this bit may be ‘1’ or ‘0’. 3.1.10.2 Internal Data Error Flag (IDE) The internal data error flag is set if a customer or OTP register data CRC fault or other internal fault is detected as defined in Section 4.5.5. The internal data error flag is cleared by a read of the DEVSTAT register. If the error is associated with a CRC fault in the writable register array, the fault will be re-asserted and will require a device reset to clear. If the error is associated with the data stored in the fuse array, the fault will be re-asserted even after a device reset. 3.1.10.3 Sigma Delta Modulator Over Range Flag (SDOV) The sigma delta modulator over range flag is set if the sigma delta modulator becomes saturated. The SDOV flag is cleared by a read of the DEVSTAT register. Table 17. Arming Threshold Registers Location Bit Address Register 7 6543210 $10 ARMT_P AT_P[7] AT_P[6] AT_P[5] AT_P[4] AT_P[3] AT_P[2] AT_P[1] AT_P[0] $12 ARMT_N AT_N[7] AT_N[6] AT_N[5] AT_N[4] AT_N[3] AT_N[2] AT_N[1] AT_N[0] Reset Value 0 0000000 Table 18. Threshold Register Value Examples Axis Type Programmed Thresholds Range (g) Sensitivity (g/LSB) Positive (Decimal) Negative (Decimal) Positive Threshold (g) Negative Threshold (g) 20 0.04097 100 50 4.10 -2.05 20 0.04097 255 0 10.45 Disabled 50 0.1024 50 20 5.12 -2.05 120 0.24414 20 10 4.88 -2.44 Table 19. Device Status Register Location Bit Address Register 7 6543210 $14 DEVSTAT UNUSED IDE SDOV DEVINIT MISOERR 0 OFFSET DEVRES |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |