13 / 56 page ![]() 2022 Microchip Technology Inc. and its subsidiaries DS20006703A-page 13 EMC2101 4.1 Modes of Operation (EMC2101-R Only) The EMC2101-R has two modes of operation based on the pull-up resistor on the ALERT pin (see Table 4-1). The modes of operation are: 1. Host Configuration Mode: an SMBus Host configures the EMC2101-R upon startup to allow for polling for temperature or fan information or the user can use the ALERT pin interrupt to determine which action is required. 2. Automatic Configuration Mode: the EMC2101-R queries an SMBus compatible EEPROM located at a known address (see Section 2.9 “Programming from EEPROM”) and automat- ically loads its registers with the contents of the EEPROM. This mode does not require host intervention but a host can poll the device for temperature and fan information. 4.2 Power Up (EMC2101-R Only) The EMC2101-R (only) will power up with the fan driver set to either 100% duty cycle or 0% duty cycle, depend- ing on the value of the pull-up resistor on the ALERT/TACH pin. (See Table 4-1.) It will remain in this state until either the Fan Setting Register is written or until the following activities have occurred: 1. The Fan Control Look-Up Table is loaded and the PROG bit is set to ‘0’ . 2. The temperature monitoring block performs its first comparison against the Look-Up Table. If the Fan Control Look-Up Table is used, the EMC2101-R Fan Driver will be immediately set to the appropriate setting in the table based on the measured temperature. 4.3 Power Modes The EMC2101 supports multiple power modes that are user configurable. The temperature monitoring and fan control functions of the device are independent. The power modes are: 1. Normal. The temperature monitoring and fan driver circuits are both active. The device updates all temperature channels at the user programmed conversion rate (see Register 5-4). Every time the temperature is updated, the limits are checked and the fan driver is updated based on the values in the Fan Control Look-Up Table (if the Fan Control Look-Up Table is enabled). 2. Standby. The temperature monitoring and fan driver circuits are both disabled. The device will not update temperature data automatically and the fan output will be set to default drive. A one-shot command can be issued that will refresh the temperature data. The limits are only checked when the temperature data is updated. 3. Mixed. The temperature monitoring block is dis- abled, but the fan driver block is active. The device will not update temperature data auto- matically and the fan driver output will not be updated automatically based on temperature. A one-shot command can be issued that will refresh the temperature data and update the fan driver based on the values in the Fan Control Look-Up Table (if the Fan Control Look-Up Table is enabled). 4.4 ALERT/TACH Output The ALERT/TACH pin (Pin 6) is an open drain output and requires a pull-up resistor to VDD when configured as an ALERT output. When configured as a TACH input, the ALERT/TACH pin will not function as an ALERT output. Error condi- tions will not trigger an interrupt (though will be updated in the Status Registers as normal) and the MASK bits will do nothing. Likewise, the device will not respond to the ARA command. For the EMC2101-R, the value of this pull-up resistor determines the initial FAN output mode of operation as well as whether the device auto loads from an EEPROM or via an SMBus host per Table 4-1. After power-up, the EMC2101-R requires 10 ms to initialize and determine the operating mode. When configured as an interrupt, the ALERT/TACH pin is maskable for each alert condition. If the ALERT/TACH pin is masked, then it will not respond to the corresponding condition (though the Alert Status Register will update normally). This pin has multiple functions described below and is controlled by ALERT_COMP bit (bit 0) in the Averaging Filter Register (BFh) (see Section 5.23 “Averaging Filter Register”). TABLE 4-1: ALERT/TACH PULL-UP RESISTORS SMBus/FAN MODE FOR EMC2101-R ALERT/TACH Pull-up Resistor SMBus Mode FAN Mode Polarity Bit Setting (See Section 5.16, Fan Configuration Register) 5.6 kΩ ±5% Host Load via SMBus FAN output initialize to 100% Duty Cycle 1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |