68 / 103 page ![]() Operation codes AN3393 68/103 DocID018750 Rev 4 This command has no parameters and it is an “Immediately executed” type. Actions: 1. SCS1 command sets register SETT2, bit D_CS to 1: – Constant Shift calculated data input type is selected for State Machine 2; – The new value of the SETT2 register is valid starting from the next step. This command affects or is affected by the following registers: – PR2: Program and Reset pointer addresses for State Machine 2; – SETT2, bit RADI: RAW data / DIFF data input type selector for State Machine 2; – CS_X / CS_Y / CS_Z: Constant Shift registers. 6.2.25 SRTAM0 (34h) The SRTAM0 command configures the R_TAM bit to preserve temporary axis mask. This command has no parameters and it is an “Immediately executed” type. Actions: 1. SRTAM0 command sets register SETTy, bit RTAM to 0: – Temporary axis mask value does not change after valid NEXT condition; – The new value of the SETTy register is valid starting from the next step. This command affects or is affected by the following registers: – PRy: Program and Reset pointer addresses; – SETTy, bit R_TAM: Temporary axis mask and peak state flag release. 6.2.26 STIM3 (41h) The STIM3 command sets Timer 3 belonging to the current State Machine to a new value (8 bits - 1st parameter). This command is an “Immediately executed” type and it takes one parameter: – new value to be set in the TIM3_y register (8 bits). Actions: 1. The STIM3 command replaces current value of the TIM3_y register address to one new byte (1st parameter) on the current State Machine: – The new value of the TIM3_y register is valid starting from the next step; – Program pointer is increased by 2 units: PPy = PPy +2. This command affects or is affected by the following registers: – PRy: Program and Reset pointer addresses; – TIM3_y: Timer 3 limit value. 6.2.27 STIM4 (42h) The STIM4 command sets Timer 4 of the current State Machine to a new value (8 bits - 1st parameter). This command is an “Immediately executed” type and it takes one parameter: – New value to be set in the TIM4_y register (8 bits). |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |