16 / 84 page ![]() M90E32AS [Datasheet] Atmel-46003B-SE-M90E32AS-Datasheet_02122015 16 3.6 MEASUREMENT FUNCTION Measured parameters can be divided to 8 types as follows: - Active/ Reactive/ Apparent Power - Fundamental/ Harmonic Power - RMS for Voltage and Current - Power Factor - Phase Angle - Frequency - Temperature - Peak Value Measured parameters are average values that are averaged among 16 phase-voltage cycles (about 320ms at 50Hz) except for the temperature. The measured parameter update frequency is approximately 3Hz. Refer to Table-17. 3.6.1 ACTIVE/ REACTIVE/ APPARENT POWER Active/ Reactive/ Apparent Power measurement registers can be divided as below: - active, reactive, apparent power - all-phase-sum / phase A / phase B / phase C Altogether there are 12 power registers. Refer to 5.6.1 Power and Power Factor Registers. Per-phase apparent power is defined as the product of measured Vrms and Irms of that phase. All-phase-sum power is measured by arithmetically summing the per-phase measured power. The summing of phases can be configured by the MMode0 register. 3.6.2 FUNDAMENTAL / HARMONIC ACTIVE POWER Fundamental / harmonic active power measurement registers can be divided as below: - fundamental and harmonic power - all-phase-sum / phase A / phase B / phase C Altogether there are 8 power registers. Refer to 5.6.2 Fundamental/ Harmonic Power and Voltage/ Current RMS Registers. 3.6.3 MEAN POWER FACTOR (PF) Power Factor is defined for those cases: all-phase-sum / phase A / phase B / phase C. Altogether there are 4 power factor registers. Refer to 5.6.1 Power and Power Factor Registers. For all-phase: For each of the phase:: 3.6.4 VOLTAGE / CURRENT RMS Voltage/current RMS registers can be divided as follows: Per-phase: Phase A / Phase B / Phase C Voltage / Current Neutral Line Current RMS: Neutral line current can be calculated by instantaneous value . Altogether there are 7 RMS registers. Refer to 5.6.2 Fundamental/ Harmonic Power and Voltage/ Current RMS Registers. ower apparent_p sum All_phase_ er active_pow sum All_phase_ = PF_all ower apparent_p er active_pow = PF_phase C B A N i i i i + + = |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |