AM79C978AVCW Datasheet(PDF) 31 Page - Advanced Micro Devices |
|
|
|||||||||||||||||||||||||||||
AM79C978AVCW Datasheet(HTML) 31 Page - Advanced Micro Devices |
|
31 / 256 page ![]() Am79C978A 31 MII Management Frames MII management frames are automatically generated by the Am79C978A controller and conform to the MII clause in the IEEE 802.3u standard. The start of the frame is a preamble of 32 ones and guarantees that all of the external PHYs are synchro- nized on the same interface. See Figure 2. Loss of synchronization is possible due to the hot-plugging capability of the exposed MII. The IEEE 802.3 specification allows you to drop the preamble, if after reading the MII Status Register from the external PHY you can determine that the external PHY will support Preamble Suppression (BCR34, bit 6). After having a valid MII Status Register read, the Am79C978A controller will then drop the creation of the preamble stream until a reset occurs, receives a read error, or the external PHY is disconnected. Figure 2. Frame Format at the MII Interface Connection This is followed by a start field (ST) and an operation field (OP). The operation field (OP) indicates whether the Am79C978A controller is initiating a read or write operation. This is followed by the external PHY ad- dress (PHYAD) and the register address (REGAD) pro- grammed in BCR33. The PHY address of 1Fh is reserved and should not be used. The external PHY may have a larger address space starting at 10h - 1Fh. This is the address range set aside by the IEEE as ven- dor usable address space and will vary from vendor to vendor. This field is followed by a bus turnaround field. During a read operation, the bus turnaround field is used to determine if the external PHY is responding correctly to the read request or not. The Am79C978A controller will tri-state the MDIO for both MDC cycles. During the second cycle, if the external PHY is syn- chronized to the Am79C978A controller, the external PHY will drive a 0. If the external PHY does not drive a 0, the Am79C978A controller will signal a MREINT (CSR7, bit 9) interrupt, if MREINTE (CSR7, bit 8) is set to a 1, indicating the Am79C978A controller had an MII management frame read error and that the data in BCR34 is not valid. The data field to/from the external PHY is read or written into the BCR34 register. The last field is an IDLE field that is necessary to give ample time for drivers to turn off before the next access. The Am79C978A controller will drive the MDC to 0 and tri- state the MDIO anytime the MII Management Port is not active. To help to speed up the reading and of writing the MII management frames to the external PHY, the MDC can be sped up to 10 MHz by setting the FMDC bits in BCR32. The IEEE 802.3 specification requires use of the 2.5-MHz clock rate, but 5 MHz and 10 MHz are avail- able for the user. The intended applications are that the 10-MHz clock rate can be used for a single external PHY on an adapter card or motherboard. The 5-MHz clock rate can be used for an exposed MII with one external PHY attached. The 2.5-MHz clock rate is intended to be used when multiple external PHYs are connected to the MII Management Port or if compliance to the IEEE 802.3u standard is required. Auto-Poll External PHY Status Polling As defined in the IEEE 802.3 standard, the external PHY attached to the Am79C978A controller’s MII has no way of communicating important timely sta- tus information back to Am79C978A controller. The Am79C978A controller has no way of knowing that an external PHY has undergone a change in status without polling the MII status register. To prevent problems from occurring with inadequate host or software polling, the Am79C978A controller will Auto-Poll when APEP (BCR32, bit 11) is set to 1 to insure that the most current information is available. See 10BASE-T PHY Management Registers for the bit descriptions of the MII Status Register. The con- tents of the latest read from the external PHY will be stored in a shadow register in the Auto-Poll block. The first read of the MII Status Register will just be stored, but subsequent reads will be compared to the contents already stored in the shadow register. If there has been a change in the contents of the MII Status Register, a MAPINT (CSR7, bit 5) interrupt will be generated on INTA if the MAPINTE (CSR7, bit 4) is set to 1. The Auto-Poll features can be dis- abled if software driver polling is required. Preamble 1111....1111 OP 10 Rd 01 Wr PHY Address Register Address TA Z0 Rd 10 Wr Data 2 Bits 5 Bits 5 Bits 2 Bits 32 Bits ST 01 2 Bits 16 Bits 1 Bit Idle Z 22399A-5 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |