| Electronic Components Datasheet Search |
|
MPC8280 Datasheet(PDF) 455 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPC8280 Datasheet(HTML) 455 Page - Freescale Semiconductor, Inc |
|
455 / 1386 page ![]() Memory Controller MPC8280 PowerQUICC II Family Reference Manual, Rev. 1 Freescale Semiconductor 11-35 11.4.1 Supported SDRAM Configurations The MPC8280 memory controller supports any SDRAM configuration under the restrictions that all SDRAM devices that reside on the same bus (60x or local) should have the same port size and timing parameters. For more information, refer to Application Note 2165, “MPC8260 SDRAM Support” (order number AN2165/D). 11.4.2 SDRAM Power-On Initialization At system reset, initialization software must set up the programmable parameters in the memory controller banks registers (ORx, BRx, P/LSDMR). After all memory parameters are configured, system software should execute the following initialization sequence for each SDRAM device. 1. Issue a PRECHARGE-ALL-BANKS command 2. Issue eight CBR REFRESH commands. If the SDRAM does not require eight CBR REFRESH commands, then the SDRAM requirement should be followed. 3. Issue a MODE-SET command to initialize the mode register The initial commands are executed by setting P/LSDMR[OP] and accessing the SDRAM with a single-byte transaction. See Figure 11-10 on page 11-20. Note that software should ensure that no memory operations begin until this process completes. 11.4.3 JEDEC-Standard SDRAM Interface Commands The MPC8280 performs all accesses to SDRAM by using JEDEC-standard SDRAM interface commands. The SDRAM device samples the command and data inputs on the rising edge of the MPC8280 bus clock. Data at the output of the SDRAM device must be sampled on the rising edge of the MPC8280 bus clock. As seen in Table 11-19, the MPC8280 provides the following SDRAM interface commands: Table 11-19. SDRAM Interface Commands Command Description Bank-activate Latches the row address and initiates a memory read of that row. Row data is latched in SDRAM sense amplifiers and must be restored with a PRECHARGE command before another BANK-ACTIVATE is issued. Mode-set Allows setting of SDRAM options—CAS latency, burst type, and burst length. CAS latency depends on the SDRAM device used (some SDRAMs provide CAS latency of 1, 2, or 3; some provide a latency of 1, 2, 3, or 4, etc.). Burst type must be chosen according to the 60x cache wrap (sequential). Although some SDRAMs provide burst lengths of 1, 2, 4, 8, or a page, MPC8280 supports only a 4-beat burst for 64-bit port size and an 8-beat burst for 32-bit port size. MPC8280 does not support burst lengths of 1, 2, and a page for SDRAMs. The mode register data (CAS latency, burst length, and burst type) is programmed into the P/LSDMR register by initialization software at reset. After the P/LSDMR is set, the MPC8280 transfers the information to the SDRAM array by issuing a MODE-SET command. Section 11.4.9, “SDRAM Mode-Set Command Timing,” gives timing information. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |