37 / 52 page ![]() 37 LTC4162-F Rev A For more information www.analog.com REGISTER DESCRIPTIONS Symbol Name Command Code Access Bit Range Default Description thermistor_ voltage_hi_alert_ limit 0x0B R/W [15:0] 0 Signed number that sets an upper limit that can be used to trigger an interrupt based on thermistor value out of range. The value is based on the A/D value for thermistor_voltage. The thermistor value can be determined by the expression RNTC = RNTCBIAS × (21829 - thermistor_voltage) / thermistor_voltage. Recall that the thermistor has a negative temperature coefficient so higher temperatures correspond to lower thermistor_voltage readings and vice-versa. The alert is enabled by setting en_thermistor_voltage_hi_alert can be read back and cleared at thermistor_voltage_hi_alert. thermistor_ voltage_lo_alert_ limit 0x0C R/W [15:0] 0 Signed number that sets a lower limit that can be used to trigger an interrupt based on thermistor value out of range. The value is based on the A/D value for thermistor_voltage. The thermistor value can be determined by the expression RNTC = RNTCBIAS × (21829 - thermistor_voltage) / thermistor_voltage. Recall that the thermistor has a negative temperature coefficient so higher temperatures correspond to lower thermistor_voltage readings and vice-versa. The alert is enabled by setting en_thermistor_voltage_lo_alert and can be read back and cleared at thermistor_voltage_lo_alert. EN_LIMIT_ ALERTS_REG 0x0D R/W [15:0] 0 Enable limit monitoring and alert notification via SMBALERT en_telemetry_ valid_alert [15] 0 To ensure high measurement accuracy, the telemetry system in the LTC4162 has a nominal start-up time of approximately 12ms. Setting this interrupt request causes an SMBALERT telemetry_valid_alert when telemetry_valid indicates that the telemetry system's readings are valid. Note that the switching battery charger will not operate until this telemetry system warmup period has passed, regardless of the state of this setting. en_bsr_done_alert [14] 0 Interrupt request that causes an SMBALERT upon bsr_done_alert when the bsr (battery- series-resistance) measurement is finished. en_vbat_lo_alert [11] 0 Interrupt request that causes an SMBALERT upon vbat_lo_alert when vbat is below vbat_lo_alert_limit. en_vbat_hi_alert [10] 0 Interrupt request that causes an SMBALERT upon vbat_hi_alert when vbat is above vbat_hi_alert_limit. en_vin_lo_alert [9] 0 Interrupt request that causes an SMBALERT upon vin_lo_alert when vin is below vin_lo_alert_limit. en_vin_hi_alert [8] 0 Interrupt request that causes an SMBALERT upon vin_hi_alert when vin is above vin_hi_alert_limit. en_vout_lo_alert [7] 0 Interrupt request that causes an SMBALERT upon vout_lo_alert when vout is below vout_lo_alert_limit. en_vout_hi_alert [6] 0 Interrupt request that causes an SMBALERT upon vout_hi_alert when vout is above vout_hi_alert_limit. en_iin_hi_alert [5] 0 Interrupt request that causes an SMBALERT upon iin_hi_alert when iin is above iin_hi_alert_limit. en_ibat_lo_alert [4] 0 Interrupt request that causes an SMBALERT upon ibat_lo_alert when ibat is below ibat_lo_alert_limit. en_die_temp_hi_ alert [3] 0 Interrupt request that causes an SMBALERT upon die_temp_hi_alert when die_temp is above die_temp_hi_alert_limit. en_bsr_hi_alert [2] 0 Interrupt request that causes an SMBALERT upon bsr_hi_alert when bsr is above bsr_hi_alert_limit. en_thermistor_ voltage_hi_alert [1] 0 Interrupt request that causes an SMBALERT upon thermistor_voltage_hi_alert when thermistor_voltageisabovethermistor_voltage_hi_alert_limit.Recallthatthethermistor hasanegativetemperaturecoefficientsohigherthermistor_voltagereadingscorrespond to lower temperatures. en_thermistor_ voltage_lo_alert [0] 0 Interrupt request that causes an SMBALERT upon thermistor_voltage_lo_alert when thermistor_voltageisbelowthermistor_voltage_lo_alert_limit.Recallthatthethermistor has a negative temperature coefficient so lower thermistor_voltage readings correspond to higher temperatures. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |