| Electronic Components Datasheet Search |
|
LTC4162EUFD-FST#PBF Datasheet(PDF) 45 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTC4162EUFD-FST#PBF Datasheet(HTML) 45 Page - Analog Devices |
|
45 / 52 page ![]() 45 LTC4162-F Rev A For more information www.analog.com Symbol Name Command Code Access Bit Range Default Description bat_short_fault_ alert [0] 0 Alert that indicates that a bat_short_fault has been detected. This alert bit is cleared by writing it back to 0 with the remaining bits in this register set to 1s. It can also be cleared by clearing en_bat_short_fault_alert. CHARGE_STATUS_ ALERTS_REG 0x38 R [5:0] 0 Alerts that charge_status indicators have occurred. Individual bits are enabled by EN_CHARGE_STATUS_ALERTS_REG. Writing 0 to any bit clears that alert. Once set, alert bits remain high until cleared or disabled. ilim_reg_active_ alert [5] 0 Alert that indicates that charge_status is ilim_reg_active. This alert bit is cleared by writing it back to 0 with the remaining bits in this register set to 1s. It can also be cleared by clearing en_ilim_reg_active_alert. thermal_reg_ active_alert [4] 0 Alert that indicates that charge_status is thermal_reg_active. This alert bit is cleared by writing it back to 0 with the remaining bits in this register set to 1s. It can also be cleared by clearing en_thermal_reg_active_alert. vin_uvcl_active_ alert [3] 0 Alert that indicates that charge_status is vin_uvcl_active. This alert bit is cleared by writing it back to 0 with the remaining bits in this register set to 1s. It can also be cleared by clearing en_vin_uvcl_active_alert. iin_limit_active_ alert [2] 0 Alertthatindicatesthatcharge_statusisiin_limit_active.Thisalertbitisclearedbywriting it back to 0 with the remaining bits in this register set to 1s. It can also be cleared by clearing en_iin_limit_active_alert. constant_current_ alert [1] 0 Alert that indicates that charge_status is constant_current. This alert bit is cleared by writing it back to 0 with the remaining bits in this register set to 1s. It can also be cleared by clearing en_constant_current_alert. constant_voltage_ alert [0] 0 Alert that indicates that charge_status is constant_voltage. This alert bit is cleared by writing it back to 0 with the remaining bits in this register set to 1s. It can also be cleared by clearing en_constant_voltage_alert. SYSTEM_STATUS_ REG 0x39 R [8:0] N/A Real time system status indicator bits en_chg [8] N/A Indicates that the battery charger is active. cell_count_err [7] N/A cell_count_err always indicates true when telemetry is not enabled such as when the charger is not enabled. no_rt [5] N/A IndicatesthatnofrequencysettingresistorisdetectedontheRTpin. TheRTpinimpedance detection circuit will typically indicate a missing RT resistor for values above 1.4MΩ. no_rt always indicates true when the battery charger is not enabled such as when there is no input power available. thermal_shutdown [4] N/A Indicates that the LTC4162 is in thermal shutdown protection due to an excessively high die temperature (typically 150°C). vin_ovlo [3] N/A Indicates that input voltage shutdown protection is active due to an input voltage above its protection shut-down threshold of approximately 38.6V. vin_gt_vbat [2] N/A Indicates that the VIN pin voltage is sufficiently above the battery voltage to begin a charge cycle (typically +150mV). vin_gt_4p2v [1] N/A Indicates that the VIN pin voltage is at least greater than the switching regulator under- voltage lockout level (4.2V typical). intvcc_gt_2p8v [0] N/A Indicates that the INTVCC pin voltage is greater than the telemetry system lockout level (2.8V typical). vbat 0x3A R [15:0] 0 Signed number that indicates the A/D measurement for the per-cell battery voltage. The value is based on the A/D scaling factor for the battery voltage measurement which is cell_count × 192.4µV/LSB at the BATSENS+ pin. vin 0x3B R [15:0] 0 Signed number that indicates the A/D measurement for the input voltage. The value is basedontheA/Dscalingfactorfortheinputvoltagemeasurementwhichis1.649mV/LSB. vout 0x3C R [15:0] 0 SignednumberthatindicatestheA/Dmeasurementforthevoutvoltage.Thevalueisbased on the A/D scaling factor for the output voltage measurement which is 1.653mV/LSB. REGISTER DESCRIPTIONS |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |