| Electronic Components Datasheet Search |
|
LTC4162EUFD-FST#PBF Datasheet(PDF) 38 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTC4162EUFD-FST#PBF Datasheet(HTML) 38 Page - Analog Devices |
|
38 / 52 page ![]() 38 LTC4162-F Rev A For more information www.analog.com REGISTER DESCRIPTIONS Symbol Name Command Code Access Bit Range Default Description EN_CHARGER_ STATE_ALERTS_ REG 0x0E R/W [12:0] 0 Enable charger state notification via SMBALERT en_bat_detect_ failed_fault_alert [12] 0 Interrupt request that causes an SMBALERT upon bat_detect_failed_fault_alert as indicated by bat_detect_failed_fault due to an inability to source power to the battery during battery detection testing (usually due to either iin_limit_active or vin_uvcl_active). en_battery_ detection_alert [11] 0 Interrupt request that causes an SMBALERT upon battery_detection_alert as indicated by battery_detection due to the LTC4162 entering battery detection testing. en_absorb_charge_ alert [9] 0 Interrupt request that causes an SMBALERT upon absorb_charge_alert when the absorb_charge phase of a battery charge cycle begins. en_charger_ suspended_alert [8] 0 Interrupt request that causes an SMBALERT upon charger_suspended_alert as indicated by charger_suspended whereby battery charging is terminated due to suspend_charger or thermistor_voltage out of jeita_t1 - jeita_t6 range. en_cc_cv_charge_ alert [6] 0 Interrupt request that causes an SMBALERT upon cc_cv_charge_alert as indicated by cc_cv_charge denoting the onset of the constant current / constant voltage phase of a battery charging cycle. en_ntc_pause_alert [5] 0 Interrupt request that causes an SMBALERT upon ntc_pause_alert as indicated by ntc_pause whereby a battery charge cycle is interrupted due to thermistor_voltage out of range as set by the jeita_t1 through jeita_t6 values. en_timer_term_ alert [4] 0 Interrupt request that causes an SMBALERT upon timer_term_alert as indicated by timer_term whereby a battery charge cycle terminates due to tcvtimer reaching max_cv_time, the maximum time allowed in constant_voltage mode. en_c_over_x_ term_alert [3] 0 Interrupt request that causes an SMBALERT upon c_over_x_term_alert as indicated by c_over_x_term whereby a battery charge cycle terminates due to ibat dropping below the c_over_x_threshold. en_max_charge_ time_alert [2] 0 Interrupt request that causes an SMBALERT upon max_charge_time_fault_alert as indicatedbymax_charge_time_faultwherebycharginghasterminatedduetotchargetimer reaching max_charge_time. en_bat_missing_ fault_alert [1] 0 Interrupt request that causes an SMBALERT upon bat_missing_fault_alert as indicated by bat_missing_fault whereby charging is prohibited if no battery is detected during the battery presence detection phase at the beginning of a charge cycle. en_bat_short_ fault_alert [0] 0 Interrupt request that causes an SMBALERT upon bat_short_fault_alert as indicated by bat_short_fault whereby charging is prohibited if a shorted battery is detected during the battery presence detection phase at the beginning of a charge cycle. EN_CHARGE_ STATUS_ALERTS_ REG 0x0F R/W [5:0] 0 Enable charge status notification via SMBALERT en_ilim_reg_ active_alert [5] 0 Interrupt request that causes an ilim_reg_active_alert SMBALERT upon ilim_reg_active (VCSP-VCSN greater than 45mV). May indicates that the switching regulator is currently controlling power delivery based on a safety current limit. This should not occur under normal conditions and is likely the result of a circuit board fault. Alternately indicates that the switching regulator is in dropout (near 100% duty cycle) and is not regulating on any feedback control loop. en_thermal_reg_ active_alert [4] 0 Interrupt request that causes a thermal_reg_active_alert SMBALERT upon thermal_reg_ active indicating that the icharge_dac is being dialed back to reduce internal die heating. en_vin_uvcl_ active_alert [3] 0 Interrupt request that causes a vin_uvcl_active_alert SMBALERT upon vin_uvcl_active indicatingthattheundervoltageregulationloophastakencontroloftheswitchingregulator. en_iin_limit_ active_alert [2] 0 Interrupt request that causes a iin_limit_active_alert SMBALERT upon iin_limit_active indicatingthattheinputcurrentregulationloophastakencontroloftheswitchingregulator. en_constant_ current_alert [1] 0 Interruptrequestthatcausesaconstant_current_alertSMBALERTuponconstant_current indicating that the battery charger constant current regulation loop has taken control of the switching regulator. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |