16 / 85 page ![]() NXP Semiconductors PCA9420 Power management IC for low-power microcontroller applications 2. During power-down sequence stage 3. During the on-the-fly change of output voltage 8.12.3 Power-up/down sequence and on-the-fly voltage change Power-up sequence The device initiates the default power-up sequence in three different conditions. Condition 1) The device is off with no any power supply (No valid VIN and No battery with 2.7 V or above attached). In this condition, two signals below are able to start the default power-up sequence. • A valid VIN supply on VIN pin • A voltage on ASYS higher than ASYS_UVLO, a 2.8 V typical Condition 2) The device stays off by enabling SHIPMODE or in SHIP mode with a battery ≥ 2.8 V attached. In this condition, two signals are able to start the default power-up sequence. • A valid VIN supply on VIN pin • A falling edge on ON key over a 200 µs Condition 3) The device stays off by enabling PWR_DN_EN bit setting to 1 with a battery ≥ 2.8 V attached. In this condition, only one signal is able to start the default power-up sequence. • A falling edge on ON key over a 200 µs Condition 4) The device stays at VIN OVP condition with no any valid supply attached at VBAT. In result, all enabled power rails have been off. The following condition re-initiates the power-up sequence. • The VIN goes below its VIN OVP hysteresis (typ 100 mV) The power-up sequence by ON key=Low over the debounce time is described as shown in Figure 7. For the power-up sequence, the chip can set the default sequence per the customer requirement at factory setting (i.e. MTP option), from one of the 64 options. Once the chip enters the power-down stage, the power- down sequence is implemented as the reverse of the power-up sequence (i.e., first up, last down). aaa-033080 POWER-UP SEQUENCE ON Key Default-On Rails Position 1 =1ms SYSRSTn POWER-OFF STATE CONTROL BY PROCESSOR TPWUP_DLY_INTERVAL (ON Long-Press Timer, 4s,8s,12s or 16s) tON_LONG_PRESS 90% 2 3 4 TON_DEBOUNCE =200µs NOTE: BUCK1, BUCK2, LDO1 and LDO2 can be assigned to any of positions 1 through 4. Positions 1 through 4 are LDO1, BUCK2, LDO2, and BUCK1. (NOTE) 3 2 1 =2ms The ON Key shall be pulled high to avoid power recycle initiated by a programmed ON long-Press timer expired PWR_DN_EN bit=1 OR SHIP_EN_x bit=1 Position 4 POWER-DOWN SEQUENCE TPWDOWN_DLY_INTERVAL Figure 7. Power-up/down sequence On-the-fly output voltage change sequence PCA9420 All information provided in this document is subject to legal disclaimers. © 2023 NXP B.V. All rights reserved. Product data sheet Rev. 4.2 — 26 July 2023 16 / 85 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |