| Electronic Components Datasheet Search |
|
MPC8280 Datasheet(PDF) 441 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPC8280 Datasheet(HTML) 441 Page - Freescale Semiconductor, Inc |
|
441 / 1386 page ![]() Memory Controller MPC8280 PowerQUICC II Family Reference Manual, Rev. 1 Freescale Semiconductor 11-21 Table 11-8. PSDMR Field Descriptions Bits Name Description 0 PBI Page-based interleaving. Selects the address multiplexing method. PBI works in conjunction with PSDMR[SDA10]. See Section 11.4.5, “Bank Interleaving.” 0 Bank-based interleaving (default at reset) 1 Page-based interleaving (recommended operation) 1 RFEN Refresh enable. Indicates that the SDRAM needs refresh services. 0 Refresh services are not required 1 Refresh services are required Note: After system reset, RFEN is cleared. See Section 11.3.8, “60x Bus-Assigned UPM Refresh Timer (PURT),” Section 11.3.9, “Local Bus-Assigned UPM Refresh Timer (LURT),” Section 11.3.10, “60x Bus-Assigned SDRAM Refresh Timer (PSRT),” and Section 11.3.11, “Local Bus-Assigned SDRAM Refresh Timer (LSRT).” 2–4 OP SDRAM operation. Determines which operation occurs when the SDRAM device is accessed. 000 Normal operation 001 CBR refresh, used in SDRAM initialization. 010 Self refresh (for debug purpose). 011 Mode Register write, used in SDRAM initialization. Note that if 60x-compatible mode is in effect on the 60x bus or the SDRAM port size is 8/16 or the SDRAM is connected to the BADDR lines (not needed for 64/32 port size), the bus master must supply the mode register data on the low bits of the address during the access. 100 Precharge bank (for debug purpose). 101 Precharge all banks, used in SDRAM initialization. 110 Activate bank (for debug purpose). 111 Read/write (for debug purpose). 5–7 SDAM Address multiplex size. Determines how the address of the current memory cycle can be output on the address pins. See Section 11.4.5.2, “SDRAM Address Multiplexing (SDAM and BSMA).” 8–10 BSMA Bank select multiplexed address line. Selects the address pins to serve as bank-select address for the 60x SDRAM. The bank select address can also be output on the BANKSEL pins (optional). See Section 11.4.5.2, “SDRAM Address Multiplexing (SDAM and BSMA).” 000 A12–A14 001 A13–A15 010 A14–A16 011 A15–A17 100 A16–A18 101 A17–A19 110 A18–A20 111 A19–A21 11–13 SDA10 “A10” control. With PSDMR[PBI], determines which address line can be output to SDA10 during an ACTIVATE command, when SDRAM is selected, to control the memory access. See Section 11.4.12.1, “SDRAM Configuration Example (Page-Based Interleaving).” For PBI = 0: 000 A12 001 A11 010 A10 011 A9 100 A8 101 A7 110 A6 111 A5 For PBI = 1: 000 A10 001 A9 010 A8 011 A7 100 A6 101 A5 110 A4 111 A3 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |