447 / 1386 page ![]() Memory Controller MPC8280 PowerQUICC II Family Reference Manual, Rev. 1 Freescale Semiconductor 11-27 Table 11-10 describes MxMR bits. Table 11-10. Machine x Mode Registers (M xMR) Bits Name Description 0 BSEL Bus select. Assigns banks that select UPM x to the 60x or local bus. 0 Banks that select UPMx are assigned to the 60x bus. 1 Banks that select UPMx are assigned to the local bus. Note: If refresh is required, the UPM’s should be assigned as follows: UPMA: 60x bus (if 60x bus refresh needed) UPMB: Local bus (if local bus refresh required) UPMC: Any bus, as long as UPMA or UPMB is used on the relevant bus. See Section 11.6.1.2, “UPM Refresh Timer Requests.” 1 RFEN Refresh enable. Indicates that the UPM needs refresh services. 0 Refresh services are not required 1 Refresh services are required See Section 11.3.8, “60x Bus-Assigned UPM Refresh Timer (PURT),” Section 11.3.9, “Local Bus-Assigned UPM Refresh Timer (LURT),” Section 11.3.10, “60x Bus-Assigned SDRAM Refresh Timer (PSRT),” and Section 11.3.11, “Local Bus-Assigned SDRAM Refresh Timer (LSRT).” 2–3 OP Command opcode. Determines the command executed by the UPMx when a memory access hit a UPM assigned bank. 00 Normal operation. 01 Write to array. On the next memory access that hits a UPM assigned bank, write the contents of the MDR into the RAM location pointed by MAD. After the access, the MAD field is automatically incremented. 10 Read from array. On the next memory access that hits a UPM assigned bank, read the contents of the RAM location pointed by MAD into the MDR. After the access, the MAD field is automatically incremented 11 Run pattern. On the next memory access that hits a UPM assigned bank, run the pattern written in the RAM array. The pattern run starts at the location pointed by MAD and continues until the LAST bit is set in the RAM. Note: RLF determines the number of times a loop is executed during a pattern run. 4 — Reserved, should be cleared. 5–7 AMx Address multiplex size. Determines how the address of the current memory cycle can be output on the address pins. The address output on the pins controlled by the contents of the UPM x RAM array. This field is useful when connecting the MPC8280 to DRAM devices requiring row and column addresses multiplexed on the same pins. See Section 11.6.4.2, “Address Multiplexing.” 8–9 DSx Disable timer period. Guarantees a minimum time between accesses to the same memory bank if it is controlled by the UPMx. The disable timer is turned on by the TODT in the RAM array, and when expired, the UPMx allows the machine access to handle a memory pattern to the same memory region. Accesses to a different memory region by the same UPMx will be allowed. 00 1-cycle disable period 01 2-cycle disable period 10 3-cycle disable period 11 4-cycle disable period Note: To avoid conflicts between successive accesses to different memory regions, the minimum pattern in the RAM array for a request serviced should not be shorter than the period established by DS x. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |