| Electronic Components Datasheet Search |
|
MPC8280 Datasheet(PDF) 743 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPC8280 Datasheet(HTML) 743 Page - Freescale Semiconductor, Inc |
|
743 / 1386 page ![]() SCC HDLC Mode MPC8280 PowerQUICC II Family Reference Manual, Rev. 1 Freescale Semiconductor 22-13 The data length and buffer pointer fields are described in Section 20.2, “SCC Buffer Descriptors (BDs).” 22.11 HDLC Event Register (SCCE)/HDLC Mask Register (SCCM) The SCC event register (SCCE) is used as the HDLC event register to report events recognized by the HDLC channel and to generate interrupts. When an event is recognized, the SCC sets the corresponding SCCE bit. Interrupts generated through SCCE can be masked in the SCC mask register (SCCM) which has the same bit format as the SCCE. Setting an SCCM bit enables the corresponding interrupt; clearing a bit masks it. SCCE bits are cleared by writing ones; writing zeros has no effect. All unmasked bits must be cleared before the CP clears the internal interrupt request. Figure 22-7 shows SCCE/SCCM for HDLC operation. Table 22-9 describes SCCE/SCCM fields. 14 UN Underrun. Set after the SCC sends a buffer and a transmitter underrun occurred. 15 CT CTS lost. Indicates when CTS in NMSI mode or layer 1 grant is lost in GCI or IDL mode during frame transmission. If data from more than one buffer is currently in the FIFO when this error occurs, the HDLC writes CT in the current BD after sending the buffer. 0 2 34 56 78 9 10 11 12 13 14 15 Field — DCC FLG IDL GRA — TXE RXF BSY TXB RXB Reset 0000_0000_0000_0000 R/W R/W Addr 0x11A10 (SCCE1); 0x11A30 (SCCE2); 0x11A50 (SCCE3); 0x11A70 (SCCE4) 0x11A14 (SCCM1); 0x11A34 (SCCM2); 0x11A54 (SCCM3); 0x11A74 (SCCM4) Figure 22-7. HDLC Event Register (SCCE)/HDLC Mask Register (SCCM) Table 22-9. SCCE/SCCM Field Descriptions 1 Bits Name Description 0–4 — Reserved, should be cleared. Refer to note 1 below. 5 DCC DPLL carrier sense changed. Set when the carrier sense status generated by the DPLL changes. Real-time status can be read in SCCS[CS]. This is not the CD status reported in port C. Valid only when the DPLL is used. 6 FLG Flag status. Set when the SCC stops or starts receiving HDLC flags. Real-time status can be read in SCCS[FG]. 7 IDL Idle sequence status changed. Set when HDLC line status changes. Real-time status of the line can be read in SCCS[ID]. 8 GRA Graceful stop complete. A GRACEFUL STOP TRANSMIT command completed execution. Set as soon as the transmitter has sent a frame in progress when the command was issued. Set immediately if no frame was in progress when the command was issued. 9–10 — Reserved, should be cleared. Refer to note 1 below. Table 22-8. SCC HDLC TxBD Status and Control Field Descriptions (continued) Bits Name Description |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |