27 / 79 page ![]() Data Sheet ADF4377 THEORY OF OPERATION analog.com Rev. 0 | 27 of 79 Figure 70. VCO Calibration Dividers Figure 71. VCO Calibration Block To perform a VCO calibration, set up several registers as outlined in the following procedure: 1. Set register bits based on the RCLK column in Table 22. 2. Set DCLK_DIV1 = 1. Set CAL_CT_SEL, DCLK_DIV2, and DCLK_MODE to the values in Table 17. Record fDIV_RCLK for later use. 3. Calculate and set the minimum values for the SYNTH_LOCK_TIMEOUT bit fields, Bits[14:0], the VCO_ALC_TIMEOUT bit fields, Bits[14:0], and the VCO_BAND_DIV bits. Typical automatic VCO calibration times are 3 ms to 9 ms when minimum values are chosen for these parameters. Larger values produce longer VCO calibration times. SYNTH_LOCK_TIMEOUT ≥Ceiling 200 μs×fDIV_RCLK (13) VCO_ALC_TIMEOUT≥Ceiling 50 μs×fDIV_RCLK (14) VCO_BAND_DIV≥Ceiling 15 μs×fDIV_RCLK 16×2DCLK_MODE (15) 4. Ensure that the ADC_CLK_DIV bits are set so that the desired ADC clock frequency is <400 kHz. ADC_CLK_DIV >Ceiling fDIV_RCLK 400 kHz −2 4 (16) 5. Set the N_INT bit fields, Bits[11:0], CLKOUT_DIV bits, R_DIV bits, and EN_RDBLR bits by programming REG0010 last. Any write to REG0010 starts the VCO automatic calibration. 6. This is an optional step. Monitor the register bits, ADC_BUSY and FSM_BUSY. The calibration is finished when ADC_BUSY transitions from high to low, followed by FSM_BUSY transition- ing from high to low. 7. After the VCO calibration is complete, disable calibration clocks to limit unwanted spurious content by setting EN_DRCLK = EN_DNCLK = EN_ADC_CLK = 0. 8. This is an optional step. Read back the VCO_CORE, VCO_BAND, and VCO_BIAS bits, and then record the read- back values. These values can be used to bypass calibration and manually program the M_VCO_CORE, M_VCO_BAND, and M_VCO_BIAS bits for a given device and frequency, as described in the Fast Power-Up and Initialization, Manually Programmed VCO Calibration Settings (Optional) section. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |