| Electronic Components Datasheet Search |
|
MPC8280 Datasheet(PDF) 1030 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPC8280 Datasheet(HTML) 1030 Page - Freescale Semiconductor, Inc |
|
1030 / 1386 page ![]() ATM Controller and AAL0, AAL1, and AAL5 MPC8280 PowerQUICC II Family Reference Manual, Rev. 1 31-70 Freescale Semiconductor Table 31-35 describes AAL5 RxBD fields. m Table 31-35. AAL5 RxBD Field Descriptions Offset Bits Name Description 0x00 0 E Empty. 0 The buffer associated with this RxBD is full or data reception was aborted due to an error. The core can read or write any fields of this RxBD. The CP does not use this BD again while E remains zero. 1 The buffer associated with this RxBD is empty or reception is in progress. This RxBD and its receive buffer are controlled by the CP. Once E is set, the core should not write any fields of this RxBD. 1 — Reserved, should be cleared. 2 W Wrap (final BD in table) 0 This is not the last BD in the RxBD table of the current channel. 1 This is the last BD in the RxBD table of this current channel. After this buffer has been used, the CP receives incoming data into the first BD in the table. The number of RxBDs in this table is programmable and is determined only by the W bit. The current table cannot exceed 64 Kbytes. 3 I Interrupt 0 No interrupt is generated after this buffer has been used. 1 An Rx buffer event is sent to the interrupt queue after the ATM controller uses this buffer. FCCE[GINT x] is set in the event register when INT_CNT reaches the global interrupt threshold. 4 L Last in frame. Set by the ATM controller for the last buffer in a frame. 0 Buffer is not last in a frame. 1 Buffer is last in a frame. ATM controller writes frame length in DL and updates the error flags. 5 F First in frame. Set by the ATM controller for the first buffer in a frame. 0 The buffer is not the first in a frame. 1 The buffer is the first in a frame. 6 CM Continuous mode 0 Normal operation. 1 The CP does not clear the empty bit after this BD is closed, allowing the associated buffer to be overwritten automatically when the CP next accesses this BD. 7–9 — Reserved, should be cleared. 10 CLP Cell loss priority. At least one cell associated with the current message was received with CLP = 1. May be set at the last buffer of the message. 11 CNG Congestion indication. The last cell associated with the current message was received with PTI middle bit set. CNG may be set at the last buffer of the message. 12 ABRT Abort message indication. The current message was received with Length field zero. 13 CPUU CPCS-UU+CPI indication. Set when the CPCS-UU+CPI field is non zero. CPUU may be set at the last buffer of the message. 14 LNE Rx length error. AAL5 CPCS-PDU length violation. May be set only for the last BD of the frame if the pad length is greater than 47 or less than zero octets. 15 CRE Rx CRC error. Indicates CRC32 error in the current AAL5 PDU. Set only for the last BD of the frame. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |