| Electronic Components Datasheet Search |
|
PIC16F18323-E/RF Datasheet(PDF) 172 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PIC16F18323-E/RF Datasheet(HTML) 172 Page - Microchip Technology |
|
172 / 442 page ![]() PIC16(L)F18313/18323 DS40001799A-page 172 Preliminary 2015 Microchip Technology Inc. 19.0 COMPLEMENTARY WAVEFORM GENERATOR (CWG) MODULE The Complementary Waveform Generator (CWG) produces complementary waveforms with dead-band delay from a selection of input sources. The CWG module has the following features: • Selectable dead-band clock source control • Selectable input sources • Output enable control • Output polarity control • Dead-band control with independent 6-bit rising and falling edge dead-band counters • Auto-shutdown control with: - Selectable shutdown sources - Auto-restart enable - Auto-shutdown pin override control 19.1 Fundamental Operation The CWG generates two output waveforms from the selected input source. The off-to-on transition of each output can be delayed from the on-to-off transition of the other output, thereby, creating a time delay immediately where neither output is driven. This is referred to as dead time and is covered in Section 19.6 “Dead-Band Control”. It may be necessary to guard against the possibility of circuit faults or a feedback event arriving too late or not at all. In this case, the active drive must be terminated before the Fault condition causes damage. This is referred to as auto-shutdown and is covered in Section 19.7 “Auto-Shutdown Control” . 19.2 Operating modes The CWG module can operate in six different modes, as specified by the MODE<2:0> bits of the CWG1CON0 register: • Half-Bridge mode • Push-Pull mode • Asynchronous Steering mode • Synchronous Steering mode • Full-Bridge mode, Forward • Full-Bridge mode, Reverse All modes accept a single pulse data input, and provide up to four outputs as described in the following sections. All modes include auto-shutdown control as described in Section 19.11 “Register Definitions: CWG Control” 19.2.1 HALF-BRIDGE MODE In Half-Bridge mode, two output signals are generated as true and inverted versions of the input as illustrated in Figure 19-1. A non-overlap (dead-band) time is inserted between the two outputs to prevent shoot through current in various power supply applications. Dead-band control is described in Section 19.6 “Dead-Band Control” . Steering modes are not used in Half-Bridge mode. The unused outputs, CWG1C and CWG1D, drive similar signals, with polarity independently controlled by POLC AND POLD, respectively. FIGURE 19-1: CWG1 HALF-BRIDGE MODE OPERATION Note: Except as noted for Full-bridge mode (Section 19.2.4 “Full-Bridge Modes”), mode changes should only be performed while EN = 0 (Register 19-1). CWG1 clock Input source CWG1A CWG1B Falling Event Dead-band Rising Event Dead-band Rising Event Dead-band Falling Event Dead-band Falling Event Dead-band Rising Event Dead-band |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |