61 / 192 page ![]() Lucent Technologies Inc. 61 Data Sheet June 1999 ORCA Series 2 FPGAs ORCA Timing Characteristics (continued) Table 15B. Derating for Commercial/Industrial Devices (OR2TxxB) Note: The derating tables shown above are for a typical critical path that contains 33% logic delay and 66% routing delay. Since the routing delay derates at a higher rate than the logic delay, paths with more than 66% routing delay will derate at a higher rate than shown in the table. The approximate derating values vs. temperature are 0.26% per °C for logic delay and 0.45% per °C for routing delay. The approximate derating values vs. voltage are 0.13% per mV for both logic and routing delays at 25 °C. In addition to supply voltage, process variation, and operating temperature, circuit and process improve- ments of the ORCA series FPGAs over time will result in significant improvement of the actual performance over those listed for a speed grade. Even though lower speed grades may still be available, the distribution of yield to timing parameters may be several speed bins higher than that designated on a product brand. Design practices need to consider best-case timing parame- ters (e.g., delays = 0), as well as worst-case timing. The routing delays are a function of fan-out and the capacitance associated with the CIPs and metal inter- connect in the path. The number of logic elements that can be driven (or fan-out) by PFUs is unlimited, although the delay to reach a valid logic level can exceed timing requirements. It is difficult to make accu- rate routing delay estimates prior to design compilation based on fan-out. This is because the CAE software may delete redundant logic inserted by the designer to reduce fan-out, and/or it may also automatically reduce fan-out by net splitting. The waveform test points are given in the Measure- ment Conditions section of this data sheet. The timing parameters given in the electrical characteristics tables in this data sheet follow industry practices, and the val- ues they reflect are described below. s Propagation Delay—the time between the specified reference points. The delays provided are the worst case of the tphh and tpll delays for noninverting func- tions, tplh and tphl for inverting functions, and tphz and tplz for 3-state enable. s Setup Time—the interval immediately preceding the transition of a clock or latch enable signal, during which the data must be stable to ensure it is recog- nized as the intended value. s Hold Time—the interval immediately following the transition of a clock or latch enable signal, during which the data must be held stable to ensure it is rec- ognized as the intended value. s 3-state Enable—the time from when a TS[3:0] signal becomes active and the output pad reaches the high- impedance state. Estimating Power Dissipation OR2CxxA The total operating power dissipated is estimated by summing the standby (IDDSB), internal, and external power dissipated. The internal and external power is the power consumed in the PLCs and PICs, respec- tively. In general, the standby power is small and may be neglected. The total operating power is as follows: PT = Σ PPLC + Σ PPIC The internal operating power is made up of two parts: clock generation and PFU output power. The PFU out- put power can be estimated based upon the number of PFU outputs switching when driving an average fan-out of two: PPFU = 0.16 mW/MHz For each PFU output that switches, 0.16 mW/MHz needs to be multiplied times the frequency (in MHz) that the output switches. Generally, this can be esti- mated by using one-half the clock rate, multiplied by some activity factor; for example, 20%. The power dissipated by the clock generation circuitry is based upon four parts: the fixed clock power, the power/clock branch row or column, the clock power dis- sipated in each PFU that uses this particular clock, and the power from the subset of those PFUs that is config- ured in either of the two synchronous modes (SSPM or SDPM). Therefore, the clock power can be calculated for the four parts using the following equations: OR2C04A Clock Power P = [0.62 mW/MHz + (0.22 mW/MHz – Branch) (# Branches) + (0.022 mW/MHz – PFU) (# PFUs) + (0.006 mW/MHz – SMEM_PFU) (# SMEM_PFUs)] fCLK For a quick estimate, the worst-case (typical circuit) OR2C04A clock power ≈ 3.9 mW/MHz. TJ (°C) Power Supply Voltage 3.0 V 3.15 V 3.3 V 3.45 V 3.6 V –40 0.81 0.78 0.76 0.74 0.73 0 0.86 0.83 0.80 0.77 0.76 25 0.9 0.87 0.83 0.8 0.78 85 1.0 0.95 0.93 0.88 0.86 100 1.02 0.98 0.95 0.91 0.88 125 1.06 1.03 0.98 0.95 0.92 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |