Back Button CS43130 Datasheet HTML 83Page - Cirrus Logic CS43130 Datasheet HTML 84Page - Cirrus Logic CS43130 Datasheet HTML 85Page - Cirrus Logic CS43130 Datasheet HTML 86Page - Cirrus Logic CS43130 Datasheet HTML 87Page - Cirrus Logic CS43130 Datasheet HTML 88Page - Cirrus Logic CS43130 Datasheet HTML 89Page - Cirrus Logic CS43130 Datasheet HTML 90Page - Cirrus Logic CS43130 Datasheet HTML 91Page - Cirrus Logic Next Button
Zoom Inzoom in Zoom Outzoom out
 87 / 137 page
background image
DS1073F1
87
CS43130
5.11 Headphone Load Measurement
5.11.3 Measuring AC Impedance at 1 kHz
Fig. 5-4 shows and Ex. 5-22 describes the steps necessary to measure AC impedance at 1 kHz with the following
assumptions:
• Continuing from Step 11 of Ex. 5-21 since DC impedance measurement is required to be run before AC impedance
measurement.
Figure 5-4. AC Impedance Measurement Flowchart
Example 5-22. AC Impedance Measurement at 1 kHz
STEP
TASK
REGISTER/BIT FIELDS
VALUE
DESCRIPTION
1
Enable impedance measurement subsystem. Refer to Ex. 5-20.
2
Check if DC impedance was already measured. Read HP Load Status (0xE001A) and verify HPLOAD_DC_ONCE (bit 8) is set.
3
Measure headphone AC impedance
4
Select Channel A
0x10010
0x99
0x10026
0x0A
0x10027
0x93
0x10028
0x0A
0x10010
0x00
HP Load 1. 0xE0000
0x80
HPLOAD_EN
Reserved
HPLOAD_CHN_SEL
Reserved
HPLOAD_AC_START
HPLOAD_DC_START
1
00
0
00
0
0
HPOUTA selected
Select Channel A
0x10010 = 0x99
0x10026 = 0x0A
0x10027 = 0x93
0x10028 = 0x0A
0x10010 = 0x00
HPLOAD_ CHN_SEL = 0 (Channel A)
HPLOAD _AC_START = 0 (Stop)
Enable DC impedance measurement
HPLOAD _AC_START = 1
HPLOAD_ AC_DONE_INT
= 1?
HPLOAD_ UNPLUG_INT
= 1?
HPLOAD_OOR _INT
= 1?
Read AC impedance
value from
RL_AC_STAT_0 and
RL_AC_STAT_ 1
YES
NO
NO
Assumptions
DAC Response
User Commands
AC Impedance Measurement
Disable Impedance Measurement Subsystem
NO
Select Channel B
0x10010 = 0x99
0x10026 = 0x8A
0x10027 = 0x15
0x10028 = 0x06
0x10010 = 0x00
HPLOAD_ CHN_SEL = 1 (Channel B )
HPLOAD _AC_START = 0 (Stop)
New
Measurement?
YES
Channel ?
B
A
Enable Impedance Measurement
Subsystem has already been run.
DC Impedance Measurement has
already been run at least once.
DC Impedance Measurement
HPLOAD _DC_ ONCE
= 1?
YES
NO
Set Frequency
HPLOAD_MEAS _FREQ_LSB = 0x??
HPLOAD _MEAS_FREQ_MSB = 0x??
YES
Error Occurred
NO
YES
Disable Impedance Measurement
Subsystem
HPLOAD_UNPLUG_ INT
= 1?
YES
NO



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com